Show filters
91 Total Results
Displaying 61-70 of 91
Sort by:
Attacker Value
Unknown
CVE-2021-35533
Disclosure Date: November 17, 2021 (last updated February 23, 2025)
Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions).
0
Attacker Value
Unknown
CVE-2021-35528
Disclosure Date: November 04, 2021 (last updated February 23, 2025)
Improper Access Control vulnerability in the application authentication and authorization of Hitachi Energy Retail Operations, Counterparty Settlement and Billing (CSB) allows an attacker to execute a modified signed Java Applet JAR file. A successful exploitation may lead to data extraction or modification of data inside the application. This issue affects: Hitachi Energy Retail Operations 5.7.3 and prior versions. Hitachi Energy Counterparty Settlement and Billing (CSB) 5.7.3 prior versions.
0
Attacker Value
Unknown
CVE-2021-35534
Disclosure Date: November 04, 2021 (last updated February 23, 2025)
Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows attacker who successfully exploited this vulnerability, of which the product does not sufficiently restrict access to an internal database tables, could allow anybody with user credentials to bypass security controls that is enforced by the product. Consequently, exploitation may lead to unauthorized modifications on data/firmware, and/or to permanently disabling the product. This issue affects: Hitachi Energy Relion 670 Series 2.0 all revisions; 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.5. Hitachi Energy Relion 670/650 Series 2.1 all revisions. 2.2.0 all revisions; 2.2.4 all revisions; Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions; 2.2.5 versions prior to 2.2.5.2. Hitachi Energy Relion 650 1.0 all revisions. 1.1 all revisions; 1.2 all revisions; 1.3 versions prior to 1.3.0.8; Hitachi Energy GMS600 1.3.0;…
0
Attacker Value
Unknown
CVE-2021-35535
Disclosure Date: November 04, 2021 (last updated February 23, 2025)
Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions.
0
Attacker Value
Unknown
CVE-2021-35529
Disclosure Date: August 05, 2021 (last updated February 23, 2025)
Insufficiently Protected Credentials vulnerability in client environment of Hitachi ABB Power Grids Retail Operations and Counterparty Settlement Billing (CSB) allows an attacker or unauthorized user to access database credentials, shut down the product and access or alter. This issue affects: Hitachi ABB Power Grids Retail Operations version 5.7.2 and prior versions. Hitachi ABB Power Grids Counterparty Settlement Billing (CSB) version 5.7.2 and prior versions.
0
Attacker Value
Unknown
CVE-2021-35527
Disclosure Date: July 14, 2021 (last updated February 23, 2025)
Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions.
0
Attacker Value
Unknown
CVE-2021-27196
Disclosure Date: March 15, 2021 (last updated February 22, 2025)
Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3…
0
Attacker Value
Unknown
CVE-2021-26845
Disclosure Date: March 08, 2021 (last updated February 22, 2025)
Information Exposure vulnerability in Hitachi ABB Power Grids eSOMS allows unauthorized user to gain access to report data if the URL used to access the report is discovered. This issue affects: Hitachi ABB Power Grids eSOMS 6.0 versions prior to 6.0.4.2.2; 6.1 versions prior to 6.1.4; 6.3 versions prior to 6.3.
0
Attacker Value
Unknown
CVE-2019-19000
Disclosure Date: April 02, 2020 (last updated February 21, 2025)
For ABB eSOMS 4.0 to 6.0.3, the Cache-Control and Pragma HTTP header(s) have not been properly configured within the application response. This can potentially allow browsers and proxies to cache sensitive information.
0
Attacker Value
Unknown
CVE-2019-19096
Disclosure Date: April 02, 2020 (last updated February 21, 2025)
The Redis data structure component used in ABB eSOMS versions 6.0 to 6.0.2 stores credentials in clear text. If an attacker has file system access, this can potentially compromise the credentials' confidentiality.
0