Unknown
CVE-2020-16216
Disclosure Date: September 11, 2020 (last updated February 22, 2025)
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750,
MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior,
the product receives input or data but does not validate or incorrectly
validates that the input has the properties required to process the data
safely and correctly, which can induce a denial-of-service condition
through a system restart.
0
Attacker Value
Unknown
CVE-2020-16214
Disclosure Date: September 11, 2020 (last updated February 22, 2025)
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software saves user-provided information into a comma-separated value
(CSV) file, but it does not neutralize or incorrectly neutralizes
special elements that could be interpreted as a command when the file is
opened by spreadsheet software.
0
Attacker Value
Unknown
CVE-2020-16222
Disclosure Date: September 11, 2020 (last updated February 22, 2025)
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and
PerformanceBridge Focal Point Version A.01, when an actor claims to have
a given identity, the software does not prove or insufficiently proves
the claim is correct.
0
Attacker Value
Unknown
CVE-2020-16228
Disclosure Date: September 11, 2020 (last updated February 22, 2025)
In Patient Information Center iX (PICiX) Versions C.02 and C.03,
PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors
MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and
prior, the software does not check or incorrectly checks the revocation
status of a certificate, which may cause it to use a compromised
certificate.
0
Attacker Value
Unknown
CVE-2020-16218
Disclosure Date: September 11, 2020 (last updated February 22, 2025)
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software does not neutralize or incorrectly neutralizes
user-controllable input before it is placed in output that is then used
as a webpage and served to other users. Successful exploitation could
lead to unauthorized access to patient data via a read-only web
application.
0
Attacker Value
Unknown
CVE-2020-11618
Disclosure Date: August 31, 2020 (last updated November 28, 2024)
THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes have their TELNET service hardcoded to start on boot, which allows an attacker on the local network to achieve root access via the TELNET protocol.
0
Attacker Value
Unknown
CVE-2020-11617
Disclosure Date: August 31, 2020 (last updated February 22, 2025)
The RSS application on THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes doesn't validate the SSL certificates of RSS servers, which allows a man-in-the-middle attacker to modify the data delivered to the client.
0
Attacker Value
Unknown
CVE-2020-16237
Disclosure Date: August 21, 2020 (last updated February 22, 2025)
Philips SureSigns VS4, A.07.107 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
0
Attacker Value
Unknown
CVE-2020-14518
Disclosure Date: August 21, 2020 (last updated February 22, 2025)
Philips DreamMapper, Version 2.24 and prior. Information written to log files can give guidance to a potential attacker.
0
Attacker Value
Unknown
CVE-2020-16239
Disclosure Date: August 21, 2020 (last updated February 22, 2025)
Philips SureSigns VS4, A.07.107 and prior. When an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
0