Show filters
113 Total Results
Displaying 41-50 of 113
Sort by:
Attacker Value
Unknown

CVE-2020-16216

Disclosure Date: September 11, 2020 (last updated February 22, 2025)
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.
Attacker Value
Unknown

CVE-2020-16214

Disclosure Date: September 11, 2020 (last updated February 22, 2025)
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a command when the file is opened by spreadsheet software.
Attacker Value
Unknown

CVE-2020-16222

Disclosure Date: September 11, 2020 (last updated February 22, 2025)
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
Attacker Value
Unknown

CVE-2020-16228

Disclosure Date: September 11, 2020 (last updated February 22, 2025)
In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.
Attacker Value
Unknown

CVE-2020-16218

Disclosure Date: September 11, 2020 (last updated February 22, 2025)
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.
Attacker Value
Unknown

CVE-2020-11618

Disclosure Date: August 31, 2020 (last updated November 28, 2024)
THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes have their TELNET service hardcoded to start on boot, which allows an attacker on the local network to achieve root access via the TELNET protocol.
Attacker Value
Unknown

CVE-2020-11617

Disclosure Date: August 31, 2020 (last updated February 22, 2025)
The RSS application on THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes doesn't validate the SSL certificates of RSS servers, which allows a man-in-the-middle attacker to modify the data delivered to the client.
Attacker Value
Unknown

CVE-2020-16237

Disclosure Date: August 21, 2020 (last updated February 22, 2025)
Philips SureSigns VS4, A.07.107 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
Attacker Value
Unknown

CVE-2020-14518

Disclosure Date: August 21, 2020 (last updated February 22, 2025)
Philips DreamMapper, Version 2.24 and prior. Information written to log files can give guidance to a potential attacker.
Attacker Value
Unknown

CVE-2020-16239

Disclosure Date: August 21, 2020 (last updated February 22, 2025)
Philips SureSigns VS4, A.07.107 and prior. When an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.