Show filters
324 Total Results
Displaying 171-180 of 324
Sort by:
Attacker Value
Unknown
CVE-2021-35528
Disclosure Date: November 04, 2021 (last updated February 23, 2025)
Improper Access Control vulnerability in the application authentication and authorization of Hitachi Energy Retail Operations, Counterparty Settlement and Billing (CSB) allows an attacker to execute a modified signed Java Applet JAR file. A successful exploitation may lead to data extraction or modification of data inside the application. This issue affects: Hitachi Energy Retail Operations 5.7.3 and prior versions. Hitachi Energy Counterparty Settlement and Billing (CSB) 5.7.3 prior versions.
0
Attacker Value
Unknown
CVE-2021-35534
Disclosure Date: November 04, 2021 (last updated February 23, 2025)
Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows attacker who successfully exploited this vulnerability, of which the product does not sufficiently restrict access to an internal database tables, could allow anybody with user credentials to bypass security controls that is enforced by the product. Consequently, exploitation may lead to unauthorized modifications on data/firmware, and/or to permanently disabling the product. This issue affects: Hitachi Energy Relion 670 Series 2.0 all revisions; 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.5. Hitachi Energy Relion 670/650 Series 2.1 all revisions. 2.2.0 all revisions; 2.2.4 all revisions; Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions; 2.2.5 versions prior to 2.2.5.2. Hitachi Energy Relion 650 1.0 all revisions. 1.1 all revisions; 1.2 all revisions; 1.3 versions prior to 1.3.0.8; Hitachi Energy GMS600 1.3.0;…
0
Attacker Value
Unknown
CVE-2021-35535
Disclosure Date: November 04, 2021 (last updated February 23, 2025)
Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions.
0
Attacker Value
Unknown
CVE-2021-29645
Disclosure Date: October 12, 2021 (last updated November 28, 2024)
Hitachi JP1/IT Desktop Management 2 Agent 9 through 12 calls the SendMessageTimeoutW API with arbitrary arguments via a local pipe, leading to a local privilege escalation vulnerability. An attacker who exploits this issue could execute arbitrary code on the local system.
0
Attacker Value
Unknown
CVE-2021-29644
Disclosure Date: October 12, 2021 (last updated February 23, 2025)
Hitachi JP1/IT Desktop Management 2 Agent 9 through 12 contains a remote code execution vulnerability because of an Integer Overflow. An attacker with network access to port 31016 may exploit this issue to execute code with unrestricted privileges on the underlying OS.
0
Attacker Value
Unknown
CVE-2021-41573
Disclosure Date: September 29, 2021 (last updated February 23, 2025)
Hitachi Content Platform Anywhere (HCP-AW) 4.4.5 and later allows information disclosure. If authenticated user creates a link to a file or folder while the system was running version 4.3.x or earlier and then shares the link and then later deletes the file or folder without deleting the link and before the link expires. If the system has been upgraded to version 4.4.5 or 4.5.0 a malicious user with the link could browse and download all files of the authenticated user that created the link .
0
Attacker Value
Unknown
CVE-2021-35526
Disclosure Date: August 31, 2021 (last updated February 23, 2025)
Backup file without encryption vulnerability is found in Hitachi ABB Power Grids System Data Manager – SDM600 allows attacker to gain access to sensitive information. This issue affects: Hitachi ABB Power Grids System Data Manager – SDM600 1.2 versions prior to FP2 HF6 (Build Nr. 1.2.14002.257).
0
Attacker Value
Unknown
CVE-2021-35529
Disclosure Date: August 05, 2021 (last updated February 23, 2025)
Insufficiently Protected Credentials vulnerability in client environment of Hitachi ABB Power Grids Retail Operations and Counterparty Settlement Billing (CSB) allows an attacker or unauthorized user to access database credentials, shut down the product and access or alter. This issue affects: Hitachi ABB Power Grids Retail Operations version 5.7.2 and prior versions. Hitachi ABB Power Grids Counterparty Settlement Billing (CSB) version 5.7.2 and prior versions.
0
Attacker Value
Unknown
CVE-2021-35527
Disclosure Date: July 14, 2021 (last updated February 23, 2025)
Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions.
0
Attacker Value
Unknown
CVE-2021-20740
Disclosure Date: June 28, 2021 (last updated February 22, 2025)
Hitachi Virtual File Platform Versions prior to 5.5.3-09 and Versions prior to 6.4.3-09, and NEC Storage M Series NAS Gateway Nh4a/Nh8a versions prior to FOS 5.5.3-08(NEC2.5.4a) and Nh4b/Nh8b, Nh4c/Nh8c versions prior to FOS 6.4.3-08(NEC3.4.2) allow remote authenticated attackers to execute arbitrary OS commands with root privileges via unspecified vectors.