Show filters
50 Total Results
Displaying 11-20 of 50
Sort by:
Attacker Value
Unknown
CVE-2022-32284
Disclosure Date: July 04, 2022 (last updated October 07, 2023)
Use of insufficiently random values vulnerability exists in Vnet/IP communication module VI461 of YOKOGAWA Wide Area Communication Router (WAC Router) AW810D, which may allow a remote attacker to cause denial-of-service (DoS) condition by sending a specially crafted packet.
0
Attacker Value
Unknown
CVE-2022-30997
Disclosure Date: June 28, 2022 (last updated October 07, 2023)
Use of hard-coded credentials vulnerability exists in STARDOM FCN Controller and FCJ Controller R4.10 to R4.31, which may allow an attacker with an administrative privilege to read/change configuration settings or update the controller with tampered firmware.
0
Attacker Value
Unknown
CVE-2022-30707
Disclosure Date: June 28, 2022 (last updated October 07, 2023)
Violation of secure design principles exists in the communication of CAMS for HIS. Affected products and versions are CENTUM series where LHS4800 is installed (CENTUM CS 3000 and CENTUM CS 3000 Small R3.08.10 to R3.09.00), CENTUM series where CAMS function is used (CENTUM VP, CENTUM VP Small, and CENTUM VP Basic R4.01.00 to R4.03.00), CENTUM series regardless of the use of CAMS function (CENTUM VP, CENTUM VP Small, and CENTUM VP Basic R5.01.00 to R5.04.20 and R6.01.00 to R6.09.00), Exaopc R3.72.00 to R3.80.00 (only if NTPF100-S6 'For CENTUM VP Support CAMS for HIS' is installed), B/M9000 CS R5.04.01 to R5.05.01, and B/M9000 VP R6.01.01 to R8.03.01). If an adjacent attacker successfully compromises a computer using CAMS for HIS software, they can use credentials from the compromised machine to access data from another machine using CAMS for HIS software. This can lead to a disabling of CAMS for HIS software functions on any affected machines, or information disclosure/alteration.
0
Attacker Value
Unknown
CVE-2022-29519
Disclosure Date: June 28, 2022 (last updated October 07, 2023)
Cleartext transmission of sensitive information vulnerability exists in STARDOM FCN Controller and FCJ Controller R1.01 to R4.31, which may allow an adjacent attacker to login the affected products and alter device configuration settings or tamper with device firmware.
0
Attacker Value
Unknown
CVE-2022-27188
Disclosure Date: April 15, 2022 (last updated October 07, 2023)
OS command injection vulnerability exists in CENTUM VP R4.01.00 to R4.03.00, CENTUM VP Small R4.01.00 to R4.03.00, CENTUM VP Basic R4.01.00 to R4.03.00, and B/M9000 VP R6.01.01 to R6.03.02, which may allow an attacker who can access the computer where the affected product is installed to execute an arbitrary OS command by altering a file generated using Graphic Builder.
0
Attacker Value
Unknown
CVE-2022-26034
Disclosure Date: April 15, 2022 (last updated October 07, 2023)
Improper authentication vulnerability in the communication protocol provided by AD (Automation Design) server of CENTUM VP R6.01.10 to R6.09.00, CENTUM VP Small R6.01.10 to R6.09.00, CENTUM VP Basic R6.01.10 to R6.09.00, and B/M9000 VP R8.01.01 to R8.03.01 allows an attacker to use the functions provided by AD server. This may lead to leakage or tampering of data managed by AD server.
0
Attacker Value
Unknown
CVE-2020-16232
Disclosure Date: March 18, 2022 (last updated October 07, 2023)
In Yokogawa WideField3 R1.01 - R4.03, a buffer overflow could be caused when a user loads a maliciously crafted project file.
0
Attacker Value
Unknown
CVE-2022-23402
Disclosure Date: March 11, 2022 (last updated October 07, 2023)
The following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00
0
Attacker Value
Unknown
CVE-2022-23401
Disclosure Date: March 11, 2022 (last updated October 07, 2023)
The following Yokogawa Electric products contain insecure DLL loading issues. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
0
Attacker Value
Unknown
CVE-2022-22729
Disclosure Date: March 11, 2022 (last updated October 07, 2023)
CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets. The authentication may be bypassed via some crafted packets: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00.
0