Unknown
CVE-2020-25150
Disclosure Date: April 14, 2022 (last updated October 07, 2023)
A relative path traversal attack in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with service user privileges to upload arbitrary files. By uploading a specially crafted tar file an attacker can execute arbitrary commands.
0
Attacker Value
Unknown
CVE-2020-16238
Disclosure Date: April 14, 2022 (last updated October 07, 2023)
A vulnerability in the configuration import mechanism of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with command line access to the underlying Linux system to escalate privileges to the root user.
0
Attacker Value
Unknown
CVE-2021-33885
Disclosure Date: August 25, 2021 (last updated February 23, 2025)
An Insufficient Verification of Data Authenticity vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote unauthenticated attacker to send the device malicious data that will be used in place of the correct data. This results in full system command access and execution because of the lack of cryptographic signatures on critical data sets.
0
Attacker Value
Unknown
CVE-2021-33882
Disclosure Date: August 25, 2021 (last updated February 23, 2025)
A Missing Authentication for Critical Function vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to reconfigure the device from an unknown source because of lack of authentication on proprietary networking commands.
0
Attacker Value
Unknown
CVE-2021-33883
Disclosure Date: August 25, 2021 (last updated February 23, 2025)
A Cleartext Transmission of Sensitive Information vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to obtain sensitive information by snooping on the network traffic. The exposed data includes critical values for a pump's internal configuration.
0
Attacker Value
Unknown
CVE-2021-33886
Disclosure Date: August 25, 2021 (last updated February 23, 2025)
An improper sanitization of input vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote unauthenticated attacker to gain user-level command-line access by passing a raw external string straight through to printf statements. The attacker is required to be on the same network as the device.
0
Attacker Value
Unknown
CVE-2021-33884
Disclosure Date: August 25, 2021 (last updated February 23, 2025)
An Unrestricted Upload of File with Dangerous Type vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows remote attackers to upload any files to the /tmp directory of the device through the webpage API. This can result in critical files being overwritten.
0
Attacker Value
Unknown
CVE-2020-25170
Disclosure Date: October 22, 2020 (last updated February 22, 2025)
An Excel Macro Injection vulnerability exists in the export feature in the B. Braun OnlineSuite Version AP 3.0 and earlier via multiple input fields that are mishandled in an Excel export.
0
Attacker Value
Unknown
CVE-2020-25172
Disclosure Date: October 22, 2020 (last updated February 22, 2025)
A relative path traversal attack in the B. Braun OnlineSuite Version AP 3.0 and earlier allows unauthenticated attackers to upload or download arbitrary files.
0
Attacker Value
Unknown
CVE-2020-25174
Disclosure Date: October 22, 2020 (last updated February 22, 2025)
A DLL hijacking vulnerability in the B. Braun OnlineSuite Version AP 3.0 and earlier allows local attackers to execute code on the system as a high privileged user.
0