Show filters
18 Total Results
Displaying 11-18 of 18
Sort by:
Attacker Value
Unknown

CVE-2023-43571

Disclosure Date: November 08, 2023 (last updated November 16, 2023)
A buffer overflow was reported in the BiosExtensionLoader module in some Lenovo Desktop products that may allow a local attacker with elevated privileges to execute arbitrary code.
Attacker Value
Unknown

CVE-2023-43570

Disclosure Date: November 08, 2023 (last updated November 17, 2023)
A potential vulnerability was reported in the SMI callback function of the OemSmi driver that may allow a local attacker with elevated permissions to execute arbitrary code.
Attacker Value
Unknown

CVE-2023-43569

Disclosure Date: November 08, 2023 (last updated November 17, 2023)
A buffer overflow was reported in the OemSmi module in some Lenovo Desktop products that may allow a local attacker with elevated privileges to execute arbitrary code. 
Attacker Value
Unknown

CVE-2023-43568

Disclosure Date: November 08, 2023 (last updated November 17, 2023)
A buffer over-read was reported in the LemSecureBootForceKey module in some Lenovo Desktop products that may allow a local attacker with elevated privileges to disclose sensitive information.
Attacker Value
Unknown

CVE-2023-43567

Disclosure Date: November 08, 2023 (last updated November 17, 2023)
A buffer overflow was reported in the LemSecureBootForceKey module in some Lenovo Desktop products that may allow a local attacker with elevated privileges to execute arbitrary code.
Attacker Value
Unknown

CVE-2022-24296

Disclosure Date: June 08, 2022 (last updated February 23, 2025)
Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System …
Attacker Value
Unknown

CVE-2021-20593

Disclosure Date: July 13, 2021 (last updated February 23, 2025)
Incorrect Implementation of Authentication Algorithm in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.2.50 to Ver. 3.35, GB-50A Ver.2.50 to Ver. 3.35, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior) and Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) allows a remote authenticated attacker to impersonate administrators to disclose configuration information of the air conditioning system and tamper information (e.g. operation information and configuration of air conditioning system) by exploiting this vulnerability.
Attacker Value
Unknown

CVE-2021-20595

Disclosure Date: July 13, 2021 (last updated February 23, 2025)
Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A Ver.9.11 and prior, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior), Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) and Air Conditioning System/BM adapter(BAC-HD150 Ver.2.21 and prior) allows a remote unauthenticated attacker to disclose some of data in the air conditioning system or cause a DoS condition by sending specially crafted packets.