Show filters
36 Total Results
Displaying 1-10 of 36
Sort by:
Attacker Value
Unknown

CVE-2020-25179

Disclosure Date: December 14, 2020 (last updated February 22, 2025)
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
Attacker Value
Unknown

CVE-2020-25175

Disclosure Date: December 14, 2020 (last updated February 22, 2025)
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
Attacker Value
Unknown

CVE-2020-6966

Disclosure Date: January 24, 2020 (last updated February 21, 2025)
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an attacker to obtain remote code execution of devices on the network.
Attacker Value
Unknown

CVE-2020-6965

Disclosure Date: January 24, 2020 (last updated February 21, 2025)
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.
Attacker Value
Unknown

CVE-2020-6963

Disclosure Date: January 24, 2020 (last updated February 21, 2025)
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.
Attacker Value
Unknown

CVE-2020-6962

Disclosure Date: January 24, 2020 (last updated February 21, 2025)
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.
Attacker Value
Unknown

CVE-2020-6961

Disclosure Date: January 24, 2020 (last updated February 21, 2025)
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.
Attacker Value
Unknown

CVE-2020-6964

Disclosure Date: January 24, 2020 (last updated February 21, 2025)
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.
Attacker Value
Unknown

CVE-2018-18630

Disclosure Date: September 06, 2019 (last updated November 27, 2024)
A vulnerability was found in McKesson Cardiology product 13.x and 14.x. Insecure file permissions in the default installation may allow an attacker with local system access to execute unauthorized arbitrary code.
Attacker Value
Unknown

CVE-2017-14101

Disclosure Date: December 15, 2017 (last updated November 26, 2024)
A security researcher found an XML External Entity (XXE) vulnerability on the Conserus Image Repository archive solution version 2.1.1.105 by McKesson Medical Imaging Company, which is now a Change Healthcare company. An unauthenticated user supplying a modified HTTP SOAP request to the vulnerable service allows for arbitrary file read access to the local file system as well as the transmittal of the application service's account hashed credentials to a remote attacker.
0