Show filters
8 Total Results
Displaying 1-8 of 8
Sort by:
Attacker Value
Unknown
CVE-2019-10981
Disclosure Date: May 31, 2019 (last updated November 27, 2024)
In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.
0
Attacker Value
Unknown
CVE-2013-2824
Disclosure Date: February 26, 2014 (last updated October 05, 2023)
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet.
0
Attacker Value
Unknown
CVE-2013-2796
Disclosure Date: August 09, 2013 (last updated October 05, 2023)
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.
0
Attacker Value
Unknown
CVE-2011-4035
Disclosure Date: December 02, 2011 (last updated October 04, 2023)
Cross-site scripting (XSS) vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
0
Attacker Value
Unknown
CVE-2011-4033
Disclosure Date: December 02, 2011 (last updated October 04, 2023)
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors.
0
Attacker Value
Unknown
CVE-2011-4036
Disclosure Date: December 02, 2011 (last updated October 04, 2023)
Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors.
0
Attacker Value
Unknown
CVE-2011-4034
Disclosure Date: December 02, 2011 (last updated October 04, 2023)
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors.
0
Attacker Value
Unknown
CVE-2011-3330
Disclosure Date: November 04, 2011 (last updated October 04, 2023)
Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter.
0