CVE-2024-10083
Disclosure Date: February 13, 2025 (last updated February 13, 2025)
CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of engineering
workstation when specific driver interface is invoked locally by an authenticated user with crafted input.
0
Attacker Value
Unknown
CVE-2023-2161
Disclosure Date: May 16, 2023 (last updated October 08, 2023)
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that
could cause unauthorized read access to the file system when a malicious configuration file is
loaded on to the software by a local user.
0
Attacker Value
Unknown
CVE-2015-1014
Disclosure Date: March 25, 2019 (last updated November 27, 2024)
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.
0
Attacker Value
Unknown
CVE-2014-0789
Disclosure Date: April 04, 2014 (last updated October 05, 2023)
Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a denial of service via long arguments to unspecified functions.
0
Attacker Value
Unknown
CVE-2013-0662
Disclosure Date: April 01, 2014 (last updated October 05, 2023)
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
0
Attacker Value
Unknown
CVE-2014-0774
Disclosure Date: February 28, 2014 (last updated October 05, 2023)
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.
0
Attacker Value
Unknown
CVE-2011-3330
Disclosure Date: November 04, 2011 (last updated October 04, 2023)
Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter.
0