Show filters
9 Total Results
Displaying 1-9 of 9
Sort by:
Attacker Value
Unknown
CVE-2020-25179
Disclosure Date: December 14, 2020 (last updated February 22, 2025)
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
0
Attacker Value
Unknown
CVE-2020-25175
Disclosure Date: December 14, 2020 (last updated February 22, 2025)
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
0
Attacker Value
Unknown
CVE-2019-11355
Disclosure Date: March 12, 2020 (last updated February 21, 2025)
An issue was discovered in Poly (formerly Polycom) HDX 3.1.13. A feature exists that allows the creation of a server / client certificate, or the upload of the user certificate, on the administrator's page. The value received from the user is the factor value of a shell script on the equipment. By entering a special character (such as a single quote) in a CN or other CSR field, one can insert a command into a factor value. A system command can be executed as root.
0
Attacker Value
Unknown
CVE-2012-6611
Disclosure Date: February 10, 2020 (last updated February 21, 2025)
An issue was discovered in Polycom Web Management Interface G3/HDX 8000 HD with Durango 2.6.0 4740 software and embedded Polycom Linux Development Platform 2.14.g3. It has a blank administrative password by default, and can be successfully used without setting this password.
0
Attacker Value
Unknown
CVE-2012-6609
Disclosure Date: January 28, 2020 (last updated February 21, 2025)
Directory traversal vulnerability in a_getlog.cgi in Polycom HDX Video End Points before 3.0.4 and UC APL before 2.7.1.J allows remote attackers to read arbitrary files via a .. (dot dot) in the name parameter.
0
Attacker Value
Unknown
CVE-2012-6610
Disclosure Date: January 28, 2020 (last updated February 21, 2025)
Polycom HDX Video End Points before 3.0.4 and UC APL before 2.7.1.J allows remote authenticated users to execute arbitrary commands as demonstrated by a ; (semicolon) to the ping command feature.
0
Attacker Value
Unknown
CVE-2018-15128
Disclosure Date: May 13, 2019 (last updated November 27, 2024)
An issue was discovered in Polycom Group Series 6.1.6.1 and earlier, HDX 3.1.12 and earlier, and Pano 1.1.1 and earlier. A remote code execution vulnerability exists in the content sharing functionality because of a Buffer Overflow via crafted packets.
0
Attacker Value
Unknown
CVE-2012-4970
Disclosure Date: January 01, 2013 (last updated October 05, 2023)
Cross-site scripting (XSS) vulnerability in the web management interface on Polycom HDX Video End Points with UC APL software before 2.7.1.1_J, and commercial software before 3.0.5, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
0
Attacker Value
Unknown
CVE-2024-3160
Last updated April 02, 2024
** DISPUTED ** ** DISPUTED ** A vulnerability, which was classified as problematic, was found in Intelbras MHDX 1004, MHDX 1008, MHDX 1016, MHDX 5016, HDCVI 1008 and HDCVI 1016 up to 20240401. This affects an unknown part of the file /cap.js of the component HTTP GET Request Handler. The manipulation leads to information disclosure. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The identifier VDB-258933 was assigned to this vulnerability. NOTE: The vendor explains that they do not classify the information shown as sensitive and therefore there is no vulnerability which is about to harm the user.
0