Show filters
247 Total Results
Displaying 51-60 of 247
Sort by:
Attacker Value
Unknown
CVE-2021-20238
Disclosure Date: April 01, 2022 (last updated February 23, 2025)
It was found in OpenShift Container Platform 4 that ignition config, served by the Machine Config Server, can be accessed externally from clusters without authentication. The MCS endpoint (port 22623) provides ignition configuration used for bootstrapping Nodes and can include some sensitive data, e.g. registry pull secrets. There are two scenarios where this data can be accessed. The first is on Baremetal, OpenStack, Ovirt, Vsphere and KubeVirt deployments which do not have a separate internal API endpoint and allow access from outside the cluster to port 22623 from the standard OpenShift API Virtual IP address. The second is on cloud deployments when using unsupported network plugins, which do not create iptables rules that prevent to port 22623. In this scenario, the ignition config is exposed to all pods within the cluster and cannot be accessed externally.
0
Attacker Value
Unknown
CVE-2021-35619
Disclosure Date: October 20, 2021 (last updated November 28, 2024)
Vulnerability in the Java VM component of Oracle Database Server. Supported versions that are affected are 12.1.0.2, 12.2.0.1, 19c and 21c. Difficult to exploit vulnerability allows low privileged attacker having Create Procedure privilege with network access via Oracle Net to compromise Java VM. Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Java VM. CVSS 3.1 Base Score 7.1 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H).
0
Attacker Value
Unknown
CVE-2021-22704
Disclosure Date: September 02, 2021 (last updated February 23, 2025)
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0) that could cause a Denial of Service or unauthorized access to system information when connecting to the Harmony HMI over FTP.
0
Attacker Value
Unknown
CVE-2021-29298
Disclosure Date: July 30, 2021 (last updated February 23, 2025)
Improper Input Validation in Emerson GE Automation Proficy Machine Edition v8.0 allows an attacker to cause a denial of service and application crash via crafted traffic from a Man-in-the-Middle (MITM) attack to the component "FrameworX.exe"in the module "fxVPStatcTcp.dll".
0
Attacker Value
Unknown
CVE-2021-29297
Disclosure Date: July 30, 2021 (last updated February 23, 2025)
Buffer Overflow in Emerson GE Automation Proficy Machine Edition v8.0 allows an attacker to cause a denial of service and application crash via crafted traffic from a Man-in-the-Middle (MITM) attack to the component "FrameworX.exe" in the module "MSVCR100.dll".
0
Attacker Value
Unknown
CVE-2021-2438
Disclosure Date: July 21, 2021 (last updated November 28, 2024)
Vulnerability in the Java VM component of Oracle Database Server. Supported versions that are affected are 12.1.0.2, 12.2.0.1 and 19c. Easily exploitable vulnerability allows low privileged attacker having Create Procedure privilege with network access via Oracle Net to compromise Java VM. Successful attacks of this vulnerability can result in unauthorized ability to cause a partial denial of service (partial DOS) of Java VM. CVSS 3.1 Base Score 4.3 (Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L).
0
Attacker Value
Unknown
CVE-2021-31892
Disclosure Date: July 13, 2021 (last updated February 23, 2025)
A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINU…
0
Attacker Value
Unknown
CVE-2020-1750
Disclosure Date: June 07, 2021 (last updated February 22, 2025)
A flaw was found in the machine-config-operator that causes an OpenShift node to become unresponsive when a container consumes a large amount of memory. An attacker could use this flaw to deny access to schedule new pods in the OpenShift cluster. This was fixed in openshift/machine-config-operator 4.4.3, openshift/machine-config-operator 4.3.25, openshift/machine-config-operator 4.2.36.
0
Attacker Value
Unknown
CVE-2021-22705
Disclosure Date: May 26, 2021 (last updated February 22, 2025)
Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert
0
Attacker Value
Unknown
CVE-2021-32471
Disclosure Date: May 10, 2021 (last updated February 22, 2025)
Insufficient input validation in the Marvin Minsky 1967 implementation of the Universal Turing Machine allows program users to execute arbitrary code via crafted data. For example, a tape head may have an unexpected location after the processing of input composed of As and Bs (instead of 0s and 1s). NOTE: the discoverer states "this vulnerability has no real-world implications."
0