Show filters
84 Total Results
Displaying 51-60 of 84
Sort by:
Attacker Value
Unknown
CVE-2020-27267
Disclosure Date: January 14, 2021 (last updated February 22, 2025)
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
0
Attacker Value
Unknown
CVE-2020-8478
Disclosure Date: April 29, 2020 (last updated February 21, 2025)
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder.
0
Attacker Value
Unknown
CVE-2020-8472
Disclosure Date: April 29, 2020 (last updated February 21, 2025)
Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
0
Attacker Value
Unknown
CVE-2015-5628
Disclosure Date: February 05, 2020 (last updated February 21, 2025)
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to execute arbitrary code via a crafted packet.
0
Attacker Value
Unknown
CVE-2015-5626
Disclosure Date: February 05, 2020 (last updated February 21, 2025)
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to cause a denial of service (network-communications outage) via a crafted packet.
0
Attacker Value
Unknown
CVE-2015-5627
Disclosure Date: February 05, 2020 (last updated February 21, 2025)
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to cause a denial of service (process outage) via a crafted packet.
0
Attacker Value
Unknown
CVE-2019-6575
Disclosure Date: April 17, 2019 (last updated November 27, 2024)
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 …
0
Attacker Value
Unknown
CVE-2015-1014
Disclosure Date: March 25, 2019 (last updated November 27, 2024)
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.
0
Attacker Value
Unknown
CVE-2018-20026
Disclosure Date: February 19, 2019 (last updated November 27, 2024)
Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.
0
Attacker Value
Unknown
CVE-2017-7457
Disclosure Date: April 14, 2017 (last updated November 26, 2024)
XML External Entity via ".AOP" files used by Moxa MX-AOPC Server 1.5 result in remote file disclosure.
0