CVE-2017-5155
Disclosure Date: February 13, 2017 (last updated November 26, 2024)
An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well.
0
Attacker Value
Unknown
CVE-2016-9360
Disclosure Date: February 13, 2017 (last updated November 26, 2024)
An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has access to an authenticated session.
0
Attacker Value
Unknown
CVE-2013-0673
Disclosure Date: May 01, 2013 (last updated October 05, 2023)
Directory traversal vulnerability in the web interface in the Health Monitor service in MatrikonOPC A&E Historian 1.0.0.0 allows remote attackers to read and delete arbitrary files via a crafted URL.
0
Attacker Value
Unknown
CVE-2012-3005
Disclosure Date: July 26, 2012 (last updated October 04, 2023)
Untrusted search path vulnerability in Invensys Wonderware InTouch 2012 and earlier, as used in Wonderware Application Server, Wonderware Information Server, Foxboro Control Software, InFusion CE/FE/SCADA, InBatch, and Wonderware Historian, allows local users to gain privileges via a Trojan horse DLL in an unspecified directory.
0
Attacker Value
Unknown
CVE-2012-2515
Disclosure Date: July 05, 2012 (last updated October 04, 2023)
Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method.
0
Attacker Value
Unknown
CVE-2012-2516
Disclosure Date: July 05, 2012 (last updated October 04, 2023)
An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module (aka the HTML Help component), as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other products, allows remote attackers to execute arbitrary commands via crafted input, related to a "command injection vulnerability."
0
Attacker Value
Unknown
CVE-2012-2559
Disclosure Date: July 05, 2012 (last updated October 04, 2023)
WellinTech KingHistorian 3.0 allows remote attackers to execute arbitrary code or cause a denial of service (invalid pointer write) via a crafted packet to TCP port 5678.
0
Attacker Value
Unknown
CVE-2012-0229
Disclosure Date: March 15, 2012 (last updated October 04, 2023)
The Data Archiver service in GE Intelligent Platforms Proficy Historian 4.5 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted session on TCP port 14000 to (1) ihDataArchiver.exe or (2) ihDataArchiver_x64.exe.
0
Attacker Value
Unknown
CVE-2011-4035
Disclosure Date: December 02, 2011 (last updated October 04, 2023)
Cross-site scripting (XSS) vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
0
Attacker Value
Unknown
CVE-2011-4033
Disclosure Date: December 02, 2011 (last updated October 04, 2023)
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors.