Show filters
524 Total Results
Displaying 351-360 of 524
Sort by:
Attacker Value
Unknown
CVE-2018-13799
Disclosure Date: September 12, 2018 (last updated November 27, 2024)
A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions < V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability could allow an attacker to compromise integrity and availability of the SIMATIC WinCC OA system. At the time of advisory publication no public exploitation of this vulnerability was known.
0
Attacker Value
Unknown
CVE-2018-12811
Disclosure Date: August 29, 2018 (last updated November 27, 2024)
Adobe Photoshop CC 2018 before 19.1.6 and Photoshop CC 2017 before 18.1.6 have a memory corruption vulnerability. Successful exploitation could lead to remote code execution.
0
Attacker Value
Unknown
CVE-2018-12810
Disclosure Date: August 29, 2018 (last updated November 27, 2024)
Adobe Photoshop CC 2018 before 19.1.6 and Photoshop CC 2017 before 18.1.6 have a memory corruption vulnerability. Successful exploitation could lead to remote code execution.
0
Attacker Value
Unknown
CVE-2018-14786
Disclosure Date: August 23, 2018 (last updated November 08, 2023)
Becton, Dickinson and Company (BD) Alaris Plus medical syringe pumps (models Alaris GS, Alaris GH, Alaris CC, and Alaris TIVA) versions 2.3.6 and prior are affected by an improper authentication vulnerability where the software does not perform authentication for functionality that requires a provable user identity, where it may allow a remote attacker to gain unauthorized access to various Alaris Syringe pumps and impact the intended operation of the pump when it is connected to a terminal server via the serial port.
0
Attacker Value
Unknown
CVE-2018-11453
Disclosure Date: August 07, 2018 (last updated November 27, 2024)
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to insert specially crafted files which may prevent TIA Portal startup (Denial-of-Service) or lead to local code execution. No special privileges are required, but the victim needs to attempt to start TIA Portal after the manipulation.
0
Attacker Value
Unknown
CVE-2018-11454
Disclosure Date: August 07, 2018 (last updated November 27, 2024)
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device.
0
Attacker Value
Unknown
CVE-2018-4858
Disclosure Date: July 09, 2018 (last updated October 17, 2023)
A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impac…
0
Attacker Value
Unknown
CVE-2018-4946
Disclosure Date: July 09, 2018 (last updated November 27, 2024)
Adobe Photoshop CC versions 19.1.3 and earlier, 18.1.3 and earlier, and 18.1.2 and earlier have an Out-of-bounds write vulnerability. Successful exploitation could lead to arbitrary code execution in the context of the current user.
0
Attacker Value
Unknown
CVE-2017-15691
Disclosure Date: April 26, 2018 (last updated November 08, 2023)
In Apache uimaj prior to 2.10.2, Apache uimaj 3.0.0-xxx prior to 3.0.0-beta, Apache uima-as prior to 2.10.2, Apache uimaFIT prior to 2.4.0, Apache uimaDUCC prior to 2.2.2, this vulnerability relates to an XML external entity expansion (XXE) capability of various XML parsers. UIMA as part of its configuration and operation may read XML from various sources, which could be tainted in ways to cause inadvertent disclosure of local files or other internal content.
0
Attacker Value
Unknown
CVE-2018-4832
Disclosure Date: April 24, 2018 (last updated November 26, 2024)
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route …
0