Show filters
524 Total Results
Displaying 341-350 of 524
Sort by:
Attacker Value
Unknown
CVE-2018-3991
Disclosure Date: February 05, 2019 (last updated November 27, 2024)
An exploitable heap overflow vulnerability exists in the WkbProgramLow function of WibuKey Network server management, version 6.40.2402.500. A specially crafted TCP packet can cause a heap overflow, potentially leading to remote code execution. An attacker can send a malformed TCP packet to trigger this vulnerability.
0
Attacker Value
Unknown
CVE-2018-20588
Disclosure Date: December 30, 2018 (last updated November 27, 2024)
lib/support/unicodeconv/unicodeconv.c in libotfcc.a in otfcc v0.10.3-alpha has a buffer over-read.
0
Attacker Value
Unknown
CVE-2018-20374
Disclosure Date: December 23, 2018 (last updated November 27, 2024)
An issue was discovered in Tiny C Compiler (aka TinyCC or TCC) 0.9.27. Compiling a crafted source file leads to an 8 byte out of bounds write in the use_section1 function in tccasm.c.
0
Attacker Value
Unknown
CVE-2018-20375
Disclosure Date: December 23, 2018 (last updated November 27, 2024)
An issue was discovered in Tiny C Compiler (aka TinyCC or TCC) 0.9.27. Compiling a crafted source file leads to an 8 byte out of bounds write in the sym_pop function in tccgen.c.
0
Attacker Value
Unknown
CVE-2018-20376
Disclosure Date: December 23, 2018 (last updated November 27, 2024)
An issue was discovered in Tiny C Compiler (aka TinyCC or TCC) 0.9.27. Compiling a crafted source file leads to an 8 byte out of bounds write in the asm_parse_directive function in tccasm.c.
0
Attacker Value
Unknown
CVE-2018-13814
Disclosure Date: December 13, 2018 (last updated November 27, 2024)
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
0
Attacker Value
Unknown
CVE-2018-13812
Disclosure Date: December 13, 2018 (last updated November 27, 2024)
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
0
Attacker Value
Unknown
CVE-2018-13813
Disclosure Date: December 13, 2018 (last updated November 27, 2024)
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
0
Attacker Value
Unknown
CVE-2018-15980
Disclosure Date: November 29, 2018 (last updated November 27, 2024)
Adobe Photoshop CC versions 19.1.6 and earlier have an out-of-bounds read vulnerability. Successful exploitation could lead to information disclosure.
0
Attacker Value
Unknown
CVE-2017-18347
Disclosure Date: September 12, 2018 (last updated November 27, 2024)
Incorrect access control in RDP Level 1 on STMicroelectronics STM32F0 series devices allows physically present attackers to extract the device's protected firmware via a special sequence of Serial Wire Debug (SWD) commands because there is a race condition between full initialization of the SWD interface and the setup of flash protection.
0