Show filters
3,317 Total Results
Displaying 341-350 of 3,317
Sort by:
Attacker Value
Unknown

CVE-2023-6408

Disclosure Date: February 14, 2024 (last updated February 26, 2025)
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack.
Attacker Value
Unknown

CVE-2023-27975

Disclosure Date: February 14, 2024 (last updated February 26, 2025)
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation.
Attacker Value
Unknown

CVE-2023-28396

Disclosure Date: February 14, 2024 (last updated February 26, 2025)
Improper access control in firmware for some Intel(R) Thunderbol(TM) Controllers versions before 41 may allow a privileged user to enable denial of service via local access.
0
Attacker Value
Unknown

CVE-2024-23789

Disclosure Date: February 14, 2024 (last updated February 26, 2025)
Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary OS command on the affected product.
0
Attacker Value
Unknown

CVE-2023-48364

Disclosure Date: February 13, 2024 (last updated February 26, 2025)
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.
Attacker Value
Unknown

CVE-2023-48363

Disclosure Date: February 13, 2024 (last updated February 26, 2025)
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain unorganized RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.
Attacker Value
Unknown

CVE-2024-25089

Disclosure Date: February 04, 2024 (last updated February 26, 2025)
Malwarebytes Binisoft Windows Firewall Control before 6.9.9.2 allows remote attackers to execute arbitrary code via gRPC named pipes.
Attacker Value
Unknown

CVE-2024-1064

Disclosure Date: February 03, 2024 (last updated February 26, 2025)
A host header injection vulnerability in the HTTP handler component of Crafty Controller allows a remote, unauthenticated attacker to trigger a Denial of Service (DoS) condition via a modified host header
Attacker Value
Unknown

CVE-2024-21916

Disclosure Date: January 31, 2024 (last updated February 26, 2025)
A denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF.
Attacker Value
Unknown

CVE-2023-5390

Disclosure Date: January 31, 2024 (last updated February 26, 2025)
An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.