Show filters
649 Total Results
Displaying 241-250 of 649
Sort by:
Attacker Value
Unknown

tcServer JMX Socket Listener Registry Rebinding Local Privilege Escalation

Disclosure Date: July 15, 2019 (last updated February 21, 2025)
In Pivotal tc Server, 3.x versions prior to 3.2.19 and 4.x versions prior to 4.0.10, and Pivotal tc Runtimes, 7.x versions prior to 7.0.99.B, 8.x versions prior to 8.5.47.A, and 9.x versions prior to 9.0.27.A, when a tc Runtime instance is configured with the JMX Socket Listener, a local attacker without access to the tc Runtime process or configuration files is able to manipulate the RMI registry to perform a man-in-the-middle attack to capture user names and passwords used to access the JMX interface. The attacker can then use these credentials to access the JMX interface and gain complete control over the tc Runtime instance.
Attacker Value
Unknown

CVE-2019-10935

Disclosure Date: July 11, 2019 (last updated November 27, 2024)
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX …
0
Attacker Value
Unknown

CVE-2019-3888

Disclosure Date: June 12, 2019 (last updated November 27, 2024)
A vulnerability was found in Undertow web server before 2.0.21. An information exposure of plain text credentials through log files because Connectors.executeRootHandler:402 logs the HttpServerExchange object at ERROR level using UndertowLogger.REQUEST_LOGGER.undertowRequestFailed(t, exchange)
Attacker Value
Unknown

CVE-2019-7090

Disclosure Date: May 24, 2019 (last updated November 27, 2024)
Flash Player Desktop Runtime versions 32.0.0.114 and earlier, Flash Player for Google Chrome versions 32.0.0.114 and earlier, and Flash Player for Microsoft Edge and Internet Explorer 11 versions 32.0.0.114 and earlier have an out-of-bounds read vulnerability. Successful exploitation could lead to information disclosure.
0
Attacker Value
Unknown

CVE-2019-7096

Disclosure Date: May 23, 2019 (last updated November 27, 2024)
Adobe Flash Player versions 32.0.0.156 and earlier, 32.0.0.156 and earlier, and 32.0.0.156 and earlier have an use after free vulnerability. Successful exploitation could lead to arbitrary code execution.
Attacker Value
Unknown

CVE-2019-7108

Disclosure Date: May 23, 2019 (last updated November 27, 2024)
Adobe Flash Player versions 32.0.0.156 and earlier, 32.0.0.156 and earlier, and 32.0.0.156 and earlier have an out-of-bounds read vulnerability. Successful exploitation could lead to information disclosure .
Attacker Value
Unknown

CVE-2019-7837

Disclosure Date: May 22, 2019 (last updated November 27, 2024)
Adobe Flash Player versions 32.0.0.171 and earlier, 32.0.0.171 and earlier, and 32.0.0.171 and earlier have a use after free vulnerability. Successful exploitation could lead to arbitrary code execution.
0
Attacker Value
Unknown

CVE-2019-6576

Disclosure Date: May 14, 2019 (last updated November 27, 2024)
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of t…
0
Attacker Value
Unknown

CVE-2019-10917

Disclosure Date: May 14, 2019 (last updated November 27, 2024)
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is l…
Attacker Value
Unknown

CVE-2019-6572

Disclosure Date: May 14, 2019 (last updated November 27, 2024)
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no publ…