Show filters
51 Total Results
Displaying 21-30 of 51
Sort by:
Attacker Value
Unknown

CVE-2021-40148

Disclosure Date: January 04, 2022 (last updated February 23, 2025)
In Modem EMM, there is a possible information disclosure due to a missing data encryption. This could lead to remote information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY00716585; Issue ID: ALPS05886933.
Attacker Value
Unknown

CVE-2021-40366

Disclosure Date: November 09, 2021 (last updated February 23, 2025)
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.42), Climatix POL909 (AWM module) (All versions < V11.34). The web server of affected devices transmits data without TLS encryption. This could allow an unauthenticated remote attacker in a man-in-the-middle position to read sensitive data, such as administrator credentials, or modify data in transit.
Attacker Value
Unknown

CVE-2020-28416

Disclosure Date: November 03, 2021 (last updated October 07, 2023)
HP has identified a security vulnerability with the I.R.I.S. OCR (Optical Character Recognition) software available with HP PageWide and OfficeJet printer software installations that could potentially allow unauthorized local code execution.
Attacker Value
Unknown

CVE-2021-31895

Disclosure Date: July 13, 2021 (last updated February 23, 2025)
A vulnerability has been identified in RUGGEDCOM ROS M2100 (All versions < V4.3.7), RUGGEDCOM ROS M2200 (All versions < V4.3.7), RUGGEDCOM ROS M969 (All versions < V4.3.7), RUGGEDCOM ROS RMC (All versions < V4.3.7), RUGGEDCOM ROS RMC20 (All versions < V4.3.7), RUGGEDCOM ROS RMC30 (All versions < V4.3.7), RUGGEDCOM ROS RMC40 (All versions < V4.3.7), RUGGEDCOM ROS RMC41 (All versions < V4.3.7), RUGGEDCOM ROS RMC8388 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RMC8388 V5.X (All versions < V5.5.4), RUGGEDCOM ROS RP110 (All versions < V4.3.7), RUGGEDCOM ROS RS400 (All versions < V4.3.7), RUGGEDCOM ROS RS401 (All versions < V4.3.7), RUGGEDCOM ROS RS416 (All versions < V4.3.7), RUGGEDCOM ROS RS416v2 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RS416v2 V5.X (All versions < 5.5.4), RUGGEDCOM ROS RS8000 (All versions < V4.3.7), RUGGEDCOM ROS RS8000A (All versions < V4.3.7), RUGGEDCOM ROS RS8000H (All versions < V4.3.7), RUGGEDCOM ROS RS8000T (All versions < V4.3.7), RUGGEDCOM ROS RS900 (32M) V4.…
Attacker Value
Unknown

CVE-2021-27372

Disclosure Date: March 25, 2021 (last updated February 22, 2025)
Realtek xPON RTL9601D SDK 1.9 stores passwords in plaintext which may allow attackers to possibly gain access to the device with root permissions via the build-in network monitoring tool and execute arbitrary commands.
Attacker Value
Unknown

CVE-2020-5655

Disclosure Date: November 02, 2020 (last updated February 22, 2025)
NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
Attacker Value
Unknown

CVE-2020-5653

Disclosure Date: November 02, 2020 (last updated February 22, 2025)
Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
Attacker Value
Unknown

CVE-2020-5654

Disclosure Date: November 02, 2020 (last updated February 22, 2025)
Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
Attacker Value
Unknown

CVE-2020-5657

Disclosure Date: November 02, 2020 (last updated February 22, 2025)
Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet.
Attacker Value
Unknown

CVE-2020-5658

Disclosure Date: November 02, 2020 (last updated November 28, 2024)
Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.