CVE-2019-6556
Disclosure Date: April 10, 2019 (last updated November 27, 2024)
When processing project files, the application (Omron CX-Programmer v9.70 and prior and Common Components January 2019 and prior) fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
0
Attacker Value
Unknown
CVE-2018-18993
Disclosure Date: December 04, 2018 (last updated November 27, 2024)
Two stack-based buffer overflow vulnerabilities have been discovered in CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior). When processing project files, the application allows input data to exceed the buffer. An attacker could use a specially crafted project file to overflow the buffer and execute code under the privileges of the application.
0
Attacker Value
Unknown
CVE-2018-18989
Disclosure Date: December 04, 2018 (last updated November 27, 2024)
In CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior), when processing project files, the application fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
0
Attacker Value
Unknown
CVE-2018-7530
Disclosure Date: April 17, 2018 (last updated November 26, 2024)
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may allow the pointer to call an incorrect object resulting in an access of resource using incompatible type condition.
0
Attacker Value
Unknown
CVE-2018-8834
Disclosure Date: April 17, 2018 (last updated November 26, 2024)
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a heap-based buffer overflow.
0
Attacker Value
Unknown
CVE-2018-7514
Disclosure Date: April 17, 2018 (last updated November 26, 2024)
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a stack-based buffer overflow.
0
Attacker Value
Unknown
CVE-2015-0988
Disclosure Date: October 06, 2015 (last updated October 05, 2023)
Omron CX-One CX-Programmer before 9.6 uses a reversible format for password storage in project source-code files, which makes it easier for local users to obtain sensitive information by reading a file.
0
Attacker Value
Unknown
CVE-2015-0987
Disclosure Date: October 06, 2015 (last updated October 05, 2023)
Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 rely on cleartext password transmission, which allows remote attackers to obtain sensitive information by sniffing the network during a PLC unlock request.
0
Attacker Value
Unknown
CVE-2015-1015
Disclosure Date: October 06, 2015 (last updated October 05, 2023)
Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 use a reversible format for password storage in object files on Compact Flash cards, which makes it easier for local users to obtain sensitive information by reading a file.
0