Show filters
232 Total Results
Displaying 121-130 of 232
Sort by:
Attacker Value
Unknown

CVE-2020-27299

Disclosure Date: January 26, 2021 (last updated February 22, 2025)
The affected product is vulnerable to an out-of-bounds read, which may allow an attacker to obtain and disclose sensitive data information or cause the device to crash on the OPC UA Tunneller (versions prior to 6.3.0.8233).
Attacker Value
Unknown

CVE-2020-27265

Disclosure Date: January 14, 2021 (last updated February 22, 2025)
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code.
Attacker Value
Unknown

CVE-2020-27263

Disclosure Date: January 14, 2021 (last updated February 22, 2025)
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
Attacker Value
Unknown

CVE-2020-27267

Disclosure Date: January 14, 2021 (last updated February 22, 2025)
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
Attacker Value
Unknown

CVE-2020-28390

Disclosure Date: January 12, 2021 (last updated February 22, 2025)
A vulnerability has been identified in Opcenter Execution Core (V8.2), Opcenter Execution Core (V8.3). The application contains an information leakage vulnerability in the handling of web client sessions. A local attacker who has access to the Web Client Session Storage could disclose the passwords of currently logged-in users.
Attacker Value
Unknown

CVE-2020-5655

Disclosure Date: November 02, 2020 (last updated February 22, 2025)
NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
Attacker Value
Unknown

CVE-2020-5653

Disclosure Date: November 02, 2020 (last updated February 22, 2025)
Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
Attacker Value
Unknown

CVE-2020-5654

Disclosure Date: November 02, 2020 (last updated February 22, 2025)
Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
Attacker Value
Unknown

CVE-2020-5657

Disclosure Date: November 02, 2020 (last updated February 22, 2025)
Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet.
Attacker Value
Unknown

CVE-2020-5658

Disclosure Date: November 02, 2020 (last updated November 28, 2024)
Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.