Show filters
887 Total Results
Displaying 11-20 of 887
Sort by:
Attacker Value
Unknown
CVE-2024-48973
Disclosure Date: November 14, 2024 (last updated November 15, 2024)
The debug port on the ventilator's serial interface is enabled by default. This could allow an attacker to send and receive messages over the debug port (which are unencrypted; see 3.2.1) that result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance.
0
Attacker Value
Unknown
CVE-2024-48971
Disclosure Date: November 14, 2024 (last updated November 15, 2024)
The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinician privileges.
0
Attacker Value
Unknown
CVE-2024-48970
Disclosure Date: November 14, 2024 (last updated November 15, 2024)
The ventilator's microcontroller lacks memory protection. An attacker could connect to the internal JTAG interface and read or write to flash memory using an off-the-shelf debugging tool, which could disrupt the function of the device and/or cause unauthorized information disclosure.
0
Attacker Value
Unknown
CVE-2024-48967
Disclosure Date: November 14, 2024 (last updated November 15, 2024)
The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, make unauthorized changes to ventilator settings that result in unauthorized disclosure of information and/or have unintended impacts on device performance.
0
Attacker Value
Unknown
CVE-2024-48966
Disclosure Date: November 14, 2024 (last updated November 15, 2024)
The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance.
0
Attacker Value
Unknown
CVE-2024-9834
Disclosure Date: November 14, 2024 (last updated November 15, 2024)
Improper data protection on the ventilator's serial interface could allow an attacker to send and receive messages that result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance.
0
Attacker Value
Unknown
CVE-2024-9832
Disclosure Date: November 14, 2024 (last updated November 15, 2024)
There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execute a brute-force attack to gain unauthorized access to the ventilator, and then make changes to device settings that could disrupt the function of the device and/or result in unauthorized information disclosure.
0
Attacker Value
Unknown
CVE-2024-47942
Disclosure Date: November 12, 2024 (last updated November 14, 2024)
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 9). The affected applications suffer from a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system.
0
Attacker Value
Unknown
CVE-2024-47941
Disclosure Date: November 12, 2024 (last updated November 14, 2024)
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 9). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
0
Attacker Value
Unknown
CVE-2024-47940
Disclosure Date: November 12, 2024 (last updated November 14, 2024)
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 9). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process.
0