Show filters
24 Total Results
Displaying 11-20 of 24
Sort by:
Attacker Value
Unknown

CVE-2024-6796

Disclosure Date: September 09, 2024 (last updated February 26, 2025)
In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal's database and/or modify content.
Attacker Value
Unknown

CVE-2024-6795

Disclosure Date: September 09, 2024 (last updated February 26, 2025)
In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal's database.  An attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content and/or perform administrative operations including shutting down the database.
Attacker Value
Unknown

CVE-2024-1275

Disclosure Date: May 31, 2024 (last updated February 26, 2025)
Use of Default Cryptographic Key vulnerability in Baxter Welch Allyn Connex Spot Monitor may allow Configuration/Environment Manipulation.This issue affects Welch Allyn Connex Spot Monitor in all versions prior to 1.52.
0
Attacker Value
Unknown

CVE-2021-38487

Disclosure Date: May 05, 2022 (last updated February 23, 2025)
RTI Connext DDS Professional, Connext DDS Secure versions 4.2x to 6.1.0, and Connext DDS Micro versions 2.4 and later are vulnerable when an attacker sends a specially crafted packet to flood target devices with unwanted traffic. This may result in a denial-of-service condition and information exposure.
Attacker Value
Unknown

CVE-2021-38435

Disclosure Date: May 05, 2022 (last updated February 23, 2025)
RTI Connext DDS Professional and Connext DDS Secure Versions 4.2x to 6.1.0 not correctly calculate the size when allocating the buffer, which may result in a buffer overflow.
Attacker Value
Unknown

CVE-2021-38433

Disclosure Date: May 05, 2022 (last updated February 23, 2025)
RTI Connext DDS Professional and Connext DDS Secure Versions 4.2x to 6.1.0 vulnerable to a stack-based buffer overflow, which may allow a local attacker to execute arbitrary code.
Attacker Value
Unknown

CVE-2021-38427

Disclosure Date: May 05, 2022 (last updated February 23, 2025)
RTI Connext DDS Professional and Connext DDS Secure Versions 4.2.x to 6.1.0 are vulnerable to a stack-based buffer overflow, which may allow a local attacker to execute arbitrary code.
Attacker Value
Unknown

CVE-2021-22801

Disclosure Date: February 11, 2022 (last updated February 23, 2025)
A CWE-269: Improper Privilege Management vulnerability exists that could cause an arbitrary command execution when the software is configured with specially crafted event actions. Affected Product: ConneXium Network Manager Software (All Versions)
Attacker Value
Unknown

CVE-2021-43935

Disclosure Date: December 09, 2021 (last updated February 23, 2025)
The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the application to accept manual entry of any active directory (AD) account provisioned in the application without supplying a password, resulting in access to the application as the supplied AD account, with all associated privileges.
Attacker Value
Unknown

CVE-2021-27408

Disclosure Date: June 11, 2021 (last updated February 22, 2025)
The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).