CVE-2021-45034

Disclosure Date: January 11, 2022
Add MITRE ATT&CK tactics and techniques that apply to this CVE.

Description

A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links.

Add Assessment

No one has assessed this topic. Be the first to add your voice to the community.

CVSS V3 Severity and Metrics
Base Score:
7.5 High
Impact Score:
3.6
Exploitability Score:
3.9
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Attack Vector (AV):
Network
Attack Complexity (AC):
Low
Privileges Required (PR):
None
User Interaction (UI):
None
Scope (S):
Unchanged
Confidentiality (C):
High
Integrity (I):
None
Availability (A):
None

General Information

Vendors

  • siemens

Products

  • cp-8000 master module with i/o -25/+70 firmware,
  • cp-8000 master module with i/o -40/+70 firmware,
  • cp-8021 master module firmware,
  • cp-8022 master module with gprs firmware