Unknown
CVE-2019-10964
CVE ID
AttackerKB requires a CVE ID in order to pull vulnerability data and references from the CVE list and the National Vulnerability Database. If available, please supply below:
Add References:
Unknown
(0 users assessed)Unknown
(0 users assessed)Unknown
Unknown
Unknown
MITRE ATT&CK
Collection
Command and Control
Credential Access
Defense Evasion
Discovery
Execution
Exfiltration
Impact
Initial Access
Lateral Movement
Persistence
Privilege Escalation
Topic Tags
Description
In Medtronic MinMed 508 and Medtronic Minimed Paradigm Insulin Pumps, Versions, MiniMed 508 pump – All versions, MiniMed Paradigm 511 pump – All versions, MiniMed Paradigm 512/712 pumps – All versions, MiniMed Paradigm 712E pump–All versions, MiniMed Paradigm 515/715 pumps–All versions, MiniMed Paradigm 522/722 pumps – All versions,MiniMed Paradigm 522K/722K pumps – All versions, MiniMed Paradigm 523/723 pumps – Software versions 2.4A or lower, MiniMed Paradigm 523K/723K pumps – Software, versions 2.4A or lower, MiniMed Paradigm Veo 554/754 pumps – Software versions 2.6A or lower, MiniMed Paradigm Veo 554CM and 754CM models only – Software versions 2.7A or lower, the affected insulin pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.
Add Assessment
No one has assessed this topic. Be the first to add your voice to the community.
CVSS V3 Severity and Metrics
General Information
Vendors
Products
- minimed 508 firmware,
- minimed paradigm 511 firmware,
- minimed paradigm 512 firmware,
- minimed paradigm 515 firmware,
- minimed paradigm 522 firmware,
- minimed paradigm 522k firmware,
- minimed paradigm 523 firmware,
- minimed paradigm 523k firmware,
- minimed paradigm 712 firmware,
- minimed paradigm 712e firmware,
- minimed paradigm 715 firmware,
- minimed paradigm 722 firmware,
- minimed paradigm 722k firmware,
- minimed paradigm 723 firmware,
- minimed paradigm 723k firmware,
- minimed paradigm veo 554 firmware,
- minimed paradigm veo 554cm firmware,
- minimed paradigm veo 754 firmware,
- minimed paradigm veo 754cm firmware -