Attacker Value
Unknown
(0 users assessed)
Exploitability
Unknown
(0 users assessed)
User Interaction
None
Privileges Required
Low
Attack Vector
Local
0

CVE-2024-47562

Disclosure Date: October 08, 2024
Add MITRE ATT&CK tactics and techniques that apply to this CVE.

Description

A vulnerability has been identified in Siemens SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly neutralize special elements in user input to the ssmctl-client command.
This could allow an authenticated, lowly privileged local attacker to execute privileged commands in the underlying OS.

Add Assessment

No one has assessed this topic. Be the first to add your voice to the community.

CVSS V3 Severity and Metrics
Base Score:
8.8 High
Impact Score:
6
Exploitability Score:
2
Vector:
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Attack Vector (AV):
Local
Attack Complexity (AC):
Low
Privileges Required (PR):
Low
User Interaction (UI):
None
Scope (S):
Changed
Confidentiality (C):
High
Integrity (I):
High
Availability (A):
High

General Information

Vendors

Additional Info

Technical Analysis