Show filters
15 Total Results
Displaying 1-10 of 15
Sort by:
Attacker Value
Unknown
CVE-2023-3643
Disclosure Date: July 12, 2023 (last updated October 08, 2023)
A vulnerability was found in Boss Mini 1.4.0 Build 6221. It has been classified as critical. This affects an unknown part of the file boss/servlet/document. The manipulation of the argument path leads to file inclusion. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-233889 was assigned to this vulnerability.
0
Attacker Value
Unknown
CVE-2020-18329
Disclosure Date: January 26, 2023 (last updated October 08, 2023)
An issue was discovered in Rehau devices that use a pCOWeb card BIOS v6.27, BOOT v5.00, web version v2.2, allows attackers to gain full unauthenticated access to the configuration and service interface.
0
Attacker Value
Unknown
CVE-2022-34827
Disclosure Date: November 18, 2022 (last updated December 22, 2024)
Carel Boss Mini 1.5.0 has Improper Access Control.
0
Attacker Value
Unknown
CVE-2022-37122
Disclosure Date: August 31, 2022 (last updated October 08, 2023)
Carel pCOWeb HVAC BACnet Gateway 2.1.0, Firmware: A2.1.0 - B2.1.0, Application Software: 2.15.4A Software v16 13020200 suffers from an unauthenticated arbitrary file disclosure vulnerability. Input passed through the 'file' GET parameter through the 'logdownload.cgi' Bash script is not properly verified before being used to download log files. This can be exploited to disclose the contents of arbitrary and sensitive files via directory traversal attacks.
0
Attacker Value
Unknown
CVE-2019-13553
Disclosure Date: October 25, 2019 (last updated November 27, 2024)
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely turning the cooling unit on and off and setting the temperature set point.
0
Attacker Value
Unknown
CVE-2019-13549
Disclosure Date: October 25, 2019 (last updated November 27, 2024)
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.
0
Attacker Value
Unknown
CVE-2019-11369
Disclosure Date: June 03, 2019 (last updated November 27, 2024)
An issue was discovered in Carel pCOWeb prior to B1.2.4. In /config/pw_changeusers.html the device stores cleartext passwords, which may allow sensitive information to be read by someone with access to the device.
0
Attacker Value
Unknown
CVE-2019-11370
Disclosure Date: June 03, 2019 (last updated November 27, 2024)
Stored XSS was discovered in Carel pCOWeb prior to B1.2.4, as demonstrated by the config/pw_snmp.html "System contact" field.
0
Attacker Value
Unknown
CVE-2019-9484
Disclosure Date: March 01, 2019 (last updated November 08, 2023)
The Glen Dimplex Deutschland GmbH implementation of the Carel pCOWeb configuration tool allows remote attackers to obtain access via an HTTP session on port 10000, as demonstrated by reading the modem password (which is 1234), or reconfiguring "party mode" or "vacation mode."
0
Attacker Value
Unknown
CVE-2016-0867
Disclosure Date: January 30, 2016 (last updated November 25, 2024)
CAREL PlantVisorEnhanced allows remote attackers to bypass intended access restrictions via a direct file request.
0