Show filters
1 Total Results
Displaying 1-1 of 1
Sort by:
Attacker Value
Unknown
Junos OS: Stateless IP firewall filter rules stop working as expected after re…
Disclosure Date: July 11, 2018 (last updated November 27, 2024)
After Junos OS device reboot or upgrade, the stateless firewall filter configuration may not take effect. This issue can be verified by running the command: user@re0> show interfaces <interface_name> extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Note: when the issue occurs, it does not show the applied firewall filter. The correct output should show the applied firewall filter, for example: user@re0> show interfaces <interface_name> extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Input Filters: FIREWAL_FILTER_NAME-<interface_name> This issue affects firewall filters for every address family. Affected releases are Juniper Networks Junos OS: 15.1R4, 15.1R5, 15.1R6 and SRs based on these MRs. 15.1X8 versions prior to 15.1X8.3.
0