Show filters
43 Total Results
Displaying 1-10 of 43
Sort by:
Attacker Value
Unknown
CVE-2023-50469
Disclosure Date: December 15, 2023 (last updated December 20, 2023)
Shenzhen Libituo Technology Co., Ltd LBT-T300-T310 v2.2.2.6 was discovered to contain a buffer overflow via the ApCliEncrypType parameter at /apply.cgi.
0
Attacker Value
Unknown
CVE-2023-47307
Disclosure Date: November 30, 2023 (last updated December 07, 2023)
Buffer Overflow vulnerability in /apply.cgi in Shenzhen Libituo Technology Co., Ltd LBT-T300-T310 v2.2.2.6 allows attackers to cause a denial of service via the ApCliAuthMode parameter.
0
Attacker Value
Unknown
CVE-2023-32350
Disclosure Date: May 22, 2023 (last updated October 08, 2023)
Versions 00.07.00 through 00.07.03 of Teltonika’s RUT router firmware contain an operating system (OS) command injection vulnerability in a Lua service. An attacker could exploit a parameter in the vulnerable function that calls a user-provided package name by instead providing a package with a malicious name that contains an OS command injection payload.
0
Attacker Value
Unknown
CVE-2023-32349
Disclosure Date: May 22, 2023 (last updated October 08, 2023)
Version 00.07.03.4 and prior of Teltonika’s RUT router firmware contain a packet dump utility that contains proper validation for filter parameters. However, variables for validation checks are stored in an external configuration file. An authenticated attacker could use an exposed UCI configuration utility to change these variables and enable malicious parameters in the dump utility, which could result in arbitrary code execution.
0
Attacker Value
Unknown
CVE-2023-0053
Disclosure Date: March 02, 2023 (last updated October 27, 2023)
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and
prior and BACnetstac version 4.2.1 and prior have only FTP and Telnet
available for device management. Any sensitive information communicated
through these protocols, such as credentials, is sent in cleartext. An
attacker could obtain sensitive information such as user credentials to
gain access to the system.
0
Attacker Value
Unknown
CVE-2023-0052
Disclosure Date: January 20, 2023 (last updated October 27, 2023)
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.
0
Attacker Value
Unknown
CVE-2020-22662
Disclosure Date: January 20, 2023 (last updated October 08, 2023)
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to change and set unauthorized "illegal region code" by remote code Execution command injection which leads to run illegal frequency with maxi output power. Vulnerability allows attacker to create an arbitrary amount of ssid wlans interface per radio which creates overhead over noise (the default max limit is 8 ssid only per radio in solo AP). Vulnerability allows attacker to unlock hidden regions by privilege command injection in WEB GUI.
0
Attacker Value
Unknown
CVE-2020-22661
Disclosure Date: January 20, 2023 (last updated October 08, 2023)
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to erase the backup secondary official image and write secondary backup unauthorized image.
0
Attacker Value
Unknown
CVE-2020-22660
Disclosure Date: January 20, 2023 (last updated October 08, 2023)
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to force bypass Secure Boot failed attempts and run temporarily the previous Backup image.
0
Attacker Value
Unknown
CVE-2020-22659
Disclosure Date: January 20, 2023 (last updated October 08, 2023)
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to exploit the official image signature to force injection unauthorized image signature.