CVE-2021-20238
Disclosure Date: April 01, 2022 (last updated February 23, 2025)
It was found in OpenShift Container Platform 4 that ignition config, served by the Machine Config Server, can be accessed externally from clusters without authentication. The MCS endpoint (port 22623) provides ignition configuration used for bootstrapping Nodes and can include some sensitive data, e.g. registry pull secrets. There are two scenarios where this data can be accessed. The first is on Baremetal, OpenStack, Ovirt, Vsphere and KubeVirt deployments which do not have a separate internal API endpoint and allow access from outside the cluster to port 22623 from the standard OpenShift API Virtual IP address. The second is on cloud deployments when using unsupported network plugins, which do not create iptables rules that prevent to port 22623. In this scenario, the ignition config is exposed to all pods within the cluster and cannot be accessed externally.
0
Attacker Value
Unknown
CVE-2020-1750
Disclosure Date: June 07, 2021 (last updated February 22, 2025)
A flaw was found in the machine-config-operator that causes an OpenShift node to become unresponsive when a container consumes a large amount of memory. An attacker could use this flaw to deny access to schedule new pods in the OpenShift cluster. This was fixed in openshift/machine-config-operator 4.4.3, openshift/machine-config-operator 4.3.25, openshift/machine-config-operator 4.2.36.