Show filters
112 Total Results
Displaying 91-100 of 112
Sort by:
Attacker Value
Unknown

CVE-2013-0674

Disclosure Date: March 21, 2013 (last updated October 05, 2023)
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.
0
Attacker Value
Unknown

CVE-2013-0678

Disclosure Date: March 21, 2013 (last updated October 05, 2023)
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query.
0
Attacker Value
Unknown

CVE-2013-0677

Disclosure Date: March 21, 2013 (last updated October 05, 2023)
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file.
0
Attacker Value
Unknown

CVE-2012-3034

Disclosure Date: September 18, 2012 (last updated October 05, 2023)
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls.
0
Attacker Value
Unknown

CVE-2012-3031

Disclosure Date: September 18, 2012 (last updated October 05, 2023)
Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header.
0
Attacker Value
Unknown

CVE-2012-3028

Disclosure Date: September 18, 2012 (last updated October 05, 2023)
Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.
0
Attacker Value
Unknown

CVE-2012-3032

Disclosure Date: September 18, 2012 (last updated October 05, 2023)
SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.
0
Attacker Value
Unknown

CVE-2012-3030

Disclosure Date: September 18, 2012 (last updated October 05, 2023)
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.
0
Attacker Value
Unknown

CVE-2011-4511

Disclosure Date: February 03, 2012 (last updated October 04, 2023)
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510.
0
Attacker Value
Unknown

CVE-2011-4875

Disclosure Date: February 03, 2012 (last updated October 04, 2023)
Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings.
0