CVE-2014-1697

Disclosure Date: February 07, 2014 (last updated October 05, 2023)
The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999.
0
Attacker Value
Unknown

CVE-2014-1696

Disclosure Date: February 07, 2014 (last updated October 05, 2023)
Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack.
0
Attacker Value
Unknown

CVE-2014-1699

Disclosure Date: February 07, 2014 (last updated October 05, 2023)
Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service (monitoring-service outage) via malformed HTTP requests to port 4999.
0
Attacker Value
Unknown

CVE-2014-1698

Disclosure Date: February 07, 2014 (last updated October 05, 2023)
Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999.
0
Attacker Value
Unknown

CVE-2013-3957

Disclosure Date: June 14, 2013 (last updated October 05, 2023)
SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
0
Attacker Value
Unknown

CVE-2013-3958

Disclosure Date: June 14, 2013 (last updated October 05, 2023)
The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request.
0
Attacker Value
Unknown

CVE-2013-3959

Disclosure Date: June 14, 2013 (last updated October 05, 2023)
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.
0
Attacker Value
Unknown

CVE-2013-0679

Disclosure Date: March 21, 2013 (last updated October 05, 2023)
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
0
Attacker Value
Unknown

CVE-2013-0676

Disclosure Date: March 21, 2013 (last updated October 05, 2023)
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query.
0
Attacker Value
Unknown

CVE-2013-0675

Disclosure Date: March 21, 2013 (last updated October 05, 2023)
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet.