Show filters
232 Total Results
Displaying 81-90 of 232
Sort by:
Attacker Value
Unknown

CVE-2022-43457

Disclosure Date: November 17, 2022 (last updated February 24, 2025)
SQL Injection in HandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
Attacker Value
Unknown

CVE-2022-43506

Disclosure Date: November 17, 2022 (last updated February 24, 2025)
SQL Injection in HandlerTag_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
Attacker Value
Unknown

CVE-2022-41775

Disclosure Date: November 17, 2022 (last updated February 24, 2025)
SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
Attacker Value
Unknown

CVE-2022-43447

Disclosure Date: November 17, 2022 (last updated February 24, 2025)
SQL Injection in AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
Attacker Value
Unknown

CVE-2022-38142

Disclosure Date: October 31, 2022 (last updated February 24, 2025)
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
Attacker Value
Unknown

CVE-2022-41657

Disclosure Date: October 31, 2022 (last updated February 24, 2025)
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.
Attacker Value
Unknown

CVE-2022-41779

Disclosure Date: October 31, 2022 (last updated February 24, 2025)
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution.
Attacker Value
Unknown

CVE-2022-41772

Disclosure Date: October 31, 2022 (last updated February 24, 2025)
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
Attacker Value
Unknown

CVE-2022-41644

Disclosure Date: October 31, 2022 (last updated February 24, 2025)
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.
Attacker Value
Unknown

CVE-2022-41629

Disclosure Date: October 31, 2022 (last updated February 24, 2025)
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.