Show filters
96 Total Results
Displaying 81-90 of 96
Sort by:
Attacker Value
Unknown
CVE-2018-4838
Disclosure Date: March 08, 2018 (last updated November 26, 2024)
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities.
0
Attacker Value
Unknown
CVE-2018-4839
Disclosure Date: March 08, 2018 (last updated November 26, 2024)
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions < V4.70), SIPROTEC 4 7SJ61 (All versions < V4.96), SIPROTEC 4 7SJ62 (All versions < V4.96), SIPROTEC 4 7SJ64 (All versions < V4.96), SIPROTEC 4 7SJ66 (All versions < V4.30), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords.
0
Attacker Value
Unknown
CVE-2018-0088
Disclosure Date: January 18, 2018 (last updated November 26, 2024)
A vulnerability in one of the diagnostic test CLI commands on Cisco Industrial Ethernet 4010 Series Switches running Cisco IOS Software could allow an authenticated, local attacker to impact the stability of the device. This could result in arbitrary code execution or a denial of service (DoS) condition. The attacker has to have valid user credentials at privilege level 15. The vulnerability is due to a diagnostic test CLI command that allows the attacker to write to the device memory. An attacker could exploit this vulnerability by authenticating to the targeted device and issuing a specific diagnostic test command at the CLI. An exploit could allow the attacker to overwrite system memory locations, which could have a negative impact on the stability of the device. Cisco Bug IDs: CSCvf71150.
0
Attacker Value
Unknown
CVE-2017-12741
Disclosure Date: December 26, 2017 (last updated July 10, 2024)
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
0
Attacker Value
Unknown
CVE-2017-9945
Disclosure Date: August 30, 2017 (last updated November 26, 2024)
In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions < V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover.
0
Attacker Value
Unknown
CVE-2017-6634
Disclosure Date: May 22, 2017 (last updated November 26, 2024)
A vulnerability in the Device Manager web interface of Cisco Industrial Ethernet 1000 Series Switches 1.3 could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack against a user of an affected system. The vulnerability is due to insufficient CSRF protection by the Device Manager web interface. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link or visit an attacker-controlled website. A successful exploit could allow the attacker to submit arbitrary requests to an affected device via the Device Manager web interface and with the privileges of the user. Cisco Bug IDs: CSCvc88811.
0
Attacker Value
Unknown
CVE-2017-2681
Disclosure Date: May 11, 2017 (last updated September 10, 2024)
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
0
Attacker Value
Unknown
CVE-2017-2680
Disclosure Date: May 11, 2017 (last updated September 10, 2024)
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
0
Attacker Value
Unknown
CVE-2017-6023
Disclosure Date: March 16, 2017 (last updated November 26, 2024)
An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device.
0
Attacker Value
Unknown
CVE-2017-3812
Disclosure Date: February 03, 2017 (last updated November 25, 2024)
A vulnerability in the implementation of Common Industrial Protocol (CIP) functionality in Cisco Industrial Ethernet 2000 Series Switches could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition due to a system memory leak. More Information: CSCvc54788. Known Affected Releases: 15.2(5.4.32i)E2. Known Fixed Releases: 15.2(5.4.62i)E2.
0