CVE-2019-10936
Disclosure Date: October 10, 2019 (last updated November 27, 2024)
Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition.
0
Attacker Value
Unknown
CVE-2019-10923
Disclosure Date: October 10, 2019 (last updated November 27, 2024)
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
0
Attacker Value
Unknown
CVE-2019-12656
Disclosure Date: September 25, 2019 (last updated November 27, 2024)
A vulnerability in the IOx application environment of multiple Cisco platforms could allow an unauthenticated, remote attacker to cause the IOx web server to stop processing HTTPS requests, resulting in a denial of service (DoS) condition. The vulnerability is due to a Transport Layer Security (TLS) implementation issue. An attacker could exploit this vulnerability by sending crafted TLS packets to the IOx web server on an affected device. A successful exploit could allow the attacker to cause the IOx web server to stop processing HTTPS requests, resulting in a DoS condition.
0
Attacker Value
Unknown
Hickory Smart Lock Cleartext Password
Disclosure Date: August 22, 2019 (last updated November 27, 2024)
A cleartext transmission of sensitive information vulnerability is present in Hickory Smart Ethernet Bridge from Belwith Products, LLC. Captured data reveals that the Hickory Smart Ethernet Bridge device communicates over the network to an MQTT broker without using encryption. This exposed the default username and password used to authenticate to the MQTT broker. This issue affects Hickory Smart Ethernet Bridge, model number H077646. The firmware does not appear to contain versioning information.
0
Attacker Value
Unknown
CVE-2019-12971
Disclosure Date: July 05, 2019 (last updated November 27, 2024)
BKS EBK Ethernet-Buskoppler Pro before 3.01 allows Unrestricted Upload of a File with a Dangerous Type.
0
Attacker Value
Unknown
CVE-2019-10953
Disclosure Date: April 17, 2019 (last updated November 27, 2024)
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
0
Attacker Value
Unknown
CVE-2018-16563
Disclosure Date: March 21, 2019 (last updated November 27, 2024)
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-M…
0
Attacker Value
Unknown
CVE-2018-16210
Disclosure Date: October 12, 2018 (last updated November 27, 2024)
WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field.
0
Attacker Value
Unknown
CVE-2016-9335
Disclosure Date: May 09, 2018 (last updated November 26, 2024)
A hard-coded cryptographic key vulnerability was identified in Red Lion Controls Sixnet-Managed Industrial Switches running firmware Version 5.0.196 and Stride-Managed Ethernet Switches running firmware Version 5.0.190. Vulnerable versions of Stride-Managed Ethernet switches and Sixnet-Managed Industrial switches use hard-coded HTTP SSL/SSH keys for secure communication. Because these keys cannot be regenerated by users, all products use the same key. The attacker could disrupt communication or compromise the system. CVSS v3 base score: 10, CVSS vector string: (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). Red Lion Controls recommends updating to SLX firmware Version 5.3.174.
0
Attacker Value
Unknown
CVE-2018-4840
Disclosure Date: March 08, 2018 (last updated November 26, 2024)
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.
0