Show filters
62 Total Results
Displaying 21-30 of 62
Sort by:
Attacker Value
Unknown
CVE-2022-48586
Disclosure Date: August 09, 2023 (last updated November 08, 2023)
A SQL injection vulnerability exists in the “json walker” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the injection of arbitrary SQL before being executed against the database.
0
Attacker Value
Unknown
CVE-2022-48585
Disclosure Date: August 09, 2023 (last updated November 08, 2023)
A SQL injection vulnerability exists in the “admin brand portal” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the injection of arbitrary SQL before being executed against the database.
0
Attacker Value
Unknown
CVE-2022-48584
Disclosure Date: August 09, 2023 (last updated November 08, 2023)
A command injection vulnerability exists in the download and convert report feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a shell command. This allows for the injection of arbitrary commands to the underlying operating system.
0
Attacker Value
Unknown
CVE-2022-48583
Disclosure Date: August 09, 2023 (last updated November 08, 2023)
A command injection vulnerability exists in the dashboard scheduler feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a shell command. This allows for the injection of arbitrary commands to the underlying operating system.
0
Attacker Value
Unknown
CVE-2022-48582
Disclosure Date: August 09, 2023 (last updated October 08, 2023)
A command injection vulnerability exists in the ticket report generate feature of the ScienceLogic SL1 that takes unsanitized user controlled input and passes it directly to a shell command. This allows for the injection of arbitrary commands to the underlying operating system.
0
Attacker Value
Unknown
CVE-2022-48581
Disclosure Date: August 09, 2023 (last updated October 08, 2023)
A command injection vulnerability exists in the “dash export” feature of the ScienceLogic SL1 that takes unsanitized user controlled input and passes it directly to a shell command. This allows for the injection of arbitrary commands to the underlying operating system.
0
Attacker Value
Unknown
CVE-2022-48580
Disclosure Date: August 09, 2023 (last updated October 08, 2023)
A command injection vulnerability exists in the ARP ping device tool feature of the ScienceLogic SL1 that takes unsanitized user controlled input and passes it directly to a shell command. This allows for the injection of arbitrary commands to the underlying operating system.
0
Attacker Value
Unknown
CVE-2021-31337
Disclosure Date: June 28, 2021 (last updated February 22, 2025)
The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
0
Attacker Value
Unknown
CVE-2021-27388
Disclosure Date: June 15, 2021 (last updated February 22, 2025)
SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control commands on the SINAMICS Medium Voltage Products, Remote Access (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
0
Attacker Value
Unknown
CVE-2021-27383
Disclosure Date: May 12, 2021 (last updated February 22, 2025)
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAM…
0