Show filters
1,150 Total Results
Displaying 171-180 of 1,150
Sort by:
Attacker Value
Unknown

CVE-2024-4123

Disclosure Date: April 24, 2024 (last updated January 16, 2025)
A vulnerability, which was classified as critical, has been found in Tenda W15E 15.11.0.14. Affected by this issue is the function formSetPortMapping of the file /goform/SetPortMapping. The manipulation of the argument portMappingServer/portMappingProtocol/portMappingWan/porMappingtInternal/portMappingExternal leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261866 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Attacker Value
Unknown

CVE-2024-4122

Disclosure Date: April 24, 2024 (last updated January 16, 2025)
A vulnerability classified as critical was found in Tenda W15E 15.11.0.14. Affected by this vulnerability is the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261865 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Attacker Value
Unknown

CVE-2024-4121

Disclosure Date: April 24, 2024 (last updated January 16, 2025)
A vulnerability classified as critical has been found in Tenda W15E 15.11.0.14. Affected is the function formQOSRuleDel. The manipulation of the argument qosIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-261864. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Attacker Value
Unknown

CVE-2024-4120

Disclosure Date: April 24, 2024 (last updated January 16, 2025)
A vulnerability was found in Tenda W15E 15.11.0.14. It has been rated as critical. This issue affects the function formIPMacBindModify of the file /goform/modifyIpMacBind. The manipulation of the argument IPMacBindRuleId/IPMacBindRuleIp/IPMacBindRuleMac/IPMacBindRuleRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261863. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Attacker Value
Unknown

CVE-2024-4119

Disclosure Date: April 24, 2024 (last updated January 16, 2025)
A vulnerability was found in Tenda W15E 15.11.0.14. It has been declared as critical. This vulnerability affects the function formIPMacBindDel of the file /goform/delIpMacBind. The manipulation of the argument IPMacBindIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261862 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Attacker Value
Unknown

CVE-2024-4118

Disclosure Date: April 24, 2024 (last updated January 16, 2025)
A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. This affects the function formIPMacBindAdd of the file /goform/addIpMacBind. The manipulation of the argument IPMacBindRule leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261861 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Attacker Value
Unknown

CVE-2024-4117

Disclosure Date: April 24, 2024 (last updated January 16, 2025)
A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this issue is the function formDelPortMapping of the file /goform/DelPortMapping. The manipulation of the argument portMappingIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261860. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Attacker Value
Unknown

CVE-2024-4116

Disclosure Date: April 24, 2024 (last updated January 16, 2025)
A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this vulnerability is the function formDelDhcpRule of the file /goform/DelDhcpRule. The manipulation of the argument delDhcpIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261859. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Attacker Value
Unknown

CVE-2024-4115

Disclosure Date: April 24, 2024 (last updated January 16, 2025)
A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Attacker Value
Unknown

CVE-2024-4114

Disclosure Date: April 24, 2024 (last updated January 28, 2025)
A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.