Show filters
1,150 Total Results
Displaying 131-140 of 1,150
Sort by:
Attacker Value
Unknown
CVE-2024-6402
Disclosure Date: June 28, 2024 (last updated August 31, 2024)
A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
0
Attacker Value
Unknown
CVE-2024-6189
Disclosure Date: June 20, 2024 (last updated November 02, 2024)
A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
0
Attacker Value
Unknown
CVE-2024-36604
Disclosure Date: June 04, 2024 (last updated December 18, 2024)
Tenda O3V2 v1.0.0.12(3880) was discovered to contain a Blind Command Injection via stpEn parameter in the SetStp function. This vulnerability allows attackers to execute arbitrary commands with root privileges.
0
Attacker Value
Unknown
CVE-2024-4497
Disclosure Date: May 05, 2024 (last updated January 28, 2025)
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
0
Attacker Value
Unknown
CVE-2024-4496
Disclosure Date: May 05, 2024 (last updated January 28, 2025)
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
0
Attacker Value
Unknown
CVE-2024-4495
Disclosure Date: May 05, 2024 (last updated January 28, 2025)
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
0
Attacker Value
Unknown
CVE-2024-4494
Disclosure Date: May 05, 2024 (last updated January 28, 2025)
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
0
Attacker Value
Unknown
CVE-2024-4493
Disclosure Date: May 05, 2024 (last updated January 28, 2025)
A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-263082 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
0
Attacker Value
Unknown
CVE-2024-4492
Disclosure Date: May 05, 2024 (last updated January 28, 2025)
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
0
Attacker Value
Unknown
CVE-2024-4491
Disclosure Date: May 05, 2024 (last updated January 28, 2025)
A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
0