Show filters
91 Total Results
Displaying 11-20 of 91
Sort by:
Attacker Value
Unknown
CVE-2024-2013
Disclosure Date: June 11, 2024 (last updated August 16, 2024)
An authentication bypass vulnerability exists in the FOXMAN-UN/UNEM server /
API Gateway component that if exploited allows attackers without
any access to interact with the services and the post-authentication
attack surface.
0
Attacker Value
Unknown
CVE-2024-2012
Disclosure Date: June 11, 2024 (last updated August 16, 2024)
vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway that if exploited an attacker could use to allow unintended commands or
code to be executed on the UNEM server allowing sensitive data to
be read or modified or could cause other unintended behavior
0
Attacker Value
Unknown
CVE-2024-2011
Disclosure Date: June 11, 2024 (last updated August 16, 2024)
A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that
if exploited will generally lead to a denial of service but can be used
to execute arbitrary code, which is usually outside the scope of a
program's implicit security policy
0
Attacker Value
Unknown
CVE-2024-28021
Disclosure Date: June 11, 2024 (last updated August 16, 2024)
A vulnerability exists in the FOXMAN-UN/UNEM server that affects the message
queueing mechanism’s certificate validation. If exploited an attacker could spoof a trusted entity causing a loss of confidentiality
and integrity.
0
Attacker Value
Unknown
CVE-2022-3864
Disclosure Date: January 04, 2024 (last updated January 11, 2024)
A vulnerability exists in the Relion update package signature validation. A tampered update package could cause the IED to restart. After restart the device is back to normal operation.
An attacker could exploit the vulnerability by first gaining access to
the system with security privileges and attempt to update the IED
with a malicious update package. Successful exploitation of this
vulnerability will cause the IED to restart, causing a temporary Denial of Service.
0
Attacker Value
Unknown
CVE-2022-2081
Disclosure Date: January 04, 2024 (last updated January 11, 2024)
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a lack of flood control which eventually if exploited causes an internal stack overflow in the HCI Modbus TCP function.
0
Attacker Value
Unknown
CVE-2023-6711
Disclosure Date: December 19, 2023 (last updated December 29, 2023)
Vulnerability exists in SCI IEC 60870-5-104 and HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Specially crafted messages sent to the mentioned components are not validated properly and can result in buffer overflow and as final consequence to a reboot of an RTU500 CMU.
0
Attacker Value
Unknown
CVE-2023-1514
Disclosure Date: December 19, 2023 (last updated December 29, 2023)
A vulnerability exists in the component RTU500 Scripting interface. When a client connects to a server using TLS, the server presents a certificate. This certificate links a public key to the identity of the service and is signed by a Certification Authority (CA), allowing the client to validate that the remote service can be trusted and is not malicious. If the client does not validate the parameters of the certificate, then attackers could be able to spoof the identity of the service. An attacker could exploit the vulnerability by using faking the identity of a RTU500 device and intercepting the messages initiated via the RTU500 Scripting interface.
0
Attacker Value
Unknown
CVE-2023-5769
Disclosure Date: December 14, 2023 (last updated December 19, 2023)
A vulnerability exists in the webserver that affects the
RTU500 series product versions listed below. A malicious
actor could perform cross-site scripting on the webserver
due to user input being improperly sanitized.
0
Attacker Value
Unknown
CVE-2023-5768
Disclosure Date: December 04, 2023 (last updated December 08, 2023)
A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below.
Incomplete or wrong received APDU frame layout may
cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer
with wrong length information of APDU or delayed reception
of data octets.
Only communication link of affected HCI IEC 60870-5-104
is blocked. If attack sequence stops the communication to
the previously attacked link gets normal again.
0