CVE-2024-6795

Disclosure Date: September 09, 2024 (last updated September 21, 2024)
In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal's database.  An attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content and/or perform administrative operations including shutting down the database.
Attacker Value
Unknown

CVE-2024-5176

Disclosure Date: May 31, 2024 (last updated June 01, 2024)
Insufficiently Protected Credentials vulnerability in Baxter Welch Allyn Configuration Tool may allow Remote Services with Stolen Credentials.This issue affects Welch Allyn Configuration Tool: versions 1.9.4.1 and prior.
0
Attacker Value
Unknown

CVE-2024-1275

Disclosure Date: May 31, 2024 (last updated June 05, 2024)
Use of Default Cryptographic Key vulnerability in Baxter Welch Allyn Connex Spot Monitor may allow Configuration/Environment Manipulation.This issue affects Welch Allyn Connex Spot Monitor in all versions prior to 1.52.
0
Attacker Value
Unknown

CVE-2022-26392

Disclosure Date: September 08, 2022 (last updated October 08, 2023)
The Baxter Spectrum WBM (v16, v16D38) and Baxter Spectrum WBM (v17, v17D19, v20D29 to v20D32) when in superuser mode is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sensitive information.
Attacker Value
Unknown

CVE-2022-26394

Disclosure Date: September 08, 2022 (last updated October 08, 2023)
The Baxter Spectrum WBM does not perform mutual authentication with the gateway server host. This may allow an attacker to perform a man in the middle attack that modifies parameters making the network connection fail.
Attacker Value
Unknown

CVE-2022-26390

Disclosure Date: September 08, 2022 (last updated October 08, 2023)
The Baxter Spectrum Wireless Battery Module (WBM) stores network credentials and PHI (only applicable to Spectrum IQ pumps using auto programming) in unencrypted form. An attacker with physical access to a device that hasn't had all data and settings erased may be able to extract sensitive information.
Attacker Value
Unknown

CVE-2022-26393

Disclosure Date: September 08, 2022 (last updated October 08, 2023)
The Baxter Spectrum WBM is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sensitive information or cause a Denial of Service (DoS) on the WBM.
Attacker Value
Unknown

CVE-2021-43935

Disclosure Date: December 09, 2021 (last updated February 23, 2025)
The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the application to accept manual entry of any active directory (AD) account provisioned in the application without supplying a password, resulting in access to the application as the supplied AD account, with all associated privileges.
Attacker Value
Unknown

CVE-2020-12012

Disclosure Date: June 29, 2020 (last updated February 21, 2025)
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 have hard-coded administrative account credentials for the ExactaMix application. Successful exploitation of this vulnerability may allow an attacker with physical access to gain unauthorized access to view/update system configuration or data. This could impact confidentiality and integrity of the system and risk exposure of sensitive information including PHI.
Attacker Value
Unknown

CVE-2020-12039

Disclosure Date: June 29, 2020 (last updated February 21, 2025)
Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed.