Show filters
20 Total Results
Displaying 11-20 of 20
Sort by:
Attacker Value
Unknown

CVE-2024-20387

Disclosure Date: October 23, 2024 (last updated January 05, 2025)
A vulnerability in the web-based management interface of Cisco FMC Software could allow an authenticated, remote attacker to store malicious content for use in XSS attacks. This vulnerability is due to improper input sanitization in the web-based management interface of Cisco FMC Software. An attacker could exploit this vulnerability by persuading a user to click a malicious link. A successful exploit could allow the attacker to conduct a stored XSS attack on an affected device.
Attacker Value
Unknown

CVE-2024-20386

Disclosure Date: October 23, 2024 (last updated January 05, 2025)
A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device. This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information.
Attacker Value
Unknown

CVE-2024-20379

Disclosure Date: October 23, 2024 (last updated January 05, 2025)
A vulnerability in the web-based management interface of Cisco Secure Firewall Management Center (FMC) Software, formerly Firepower Management Center Software, could allow an authenticated, remote attacker to read arbitrary files from the underlying operating system. This vulnerability exists because the web-based management interface does not properly validate user-supplied input. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device. A successful exploit could allow the attacker to read arbitrary files on the underlying operating system of the affected device. The attacker would need valid user credentials to exploit this vulnerability.
Attacker Value
Unknown

CVE-2024-20372

Disclosure Date: October 23, 2024 (last updated January 05, 2025)
A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device. This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information.
Attacker Value
Unknown

CVE-2024-20364

Disclosure Date: October 23, 2024 (last updated November 01, 2024)
A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device. This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information.
Attacker Value
Unknown

CVE-2024-20340

Disclosure Date: October 23, 2024 (last updated November 02, 2024)
A vulnerability in the web-based management interface of Cisco Secure Firewall Management Center (FMC) Software, formerly Firepower Management Center Software, could allow an authenticated, remote attacker to perform an SQL injection attack against an affected device. To exploit this vulnerability, an attacker must have a valid account on the device with the role of Security Approver, Intrusion Admin, Access Admin, or Network Admin. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a crafted HTTP request to the web-based management interface of an affected device. A successful exploit could allow the attacker to read the contents of databases on the affected device and also obtain limited read access to the underlying operating system.
Attacker Value
Unknown

CVE-2024-20300

Disclosure Date: October 23, 2024 (last updated November 02, 2024)
A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface of an affected device. This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information.
Attacker Value
Unknown

CVE-2024-20298

Disclosure Date: October 23, 2024 (last updated November 01, 2024)
A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface of an affected device. This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information.
Attacker Value
Unknown

CVE-2024-20273

Disclosure Date: October 23, 2024 (last updated November 01, 2024)
A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface of an affected device. This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information.
Attacker Value
Unknown

CVE-2024-20269

Disclosure Date: October 23, 2024 (last updated November 01, 2024)
A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface of an affected device. This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information.