Show filters
15 Total Results
Displaying 11-15 of 15
Sort by:
Attacker Value
Unknown
CVE-2024-2806
Disclosure Date: March 22, 2024 (last updated April 11, 2024)
A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
0
Attacker Value
Unknown
CVE-2024-2805
Disclosure Date: March 22, 2024 (last updated January 25, 2025)
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257660. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
0
Attacker Value
Unknown
CVE-2022-28557
Disclosure Date: May 04, 2022 (last updated February 23, 2025)
There is a command injection vulnerability at the /goform/setsambacfg interface of Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin device web, which can also cooperate with CVE-2021-44971 to cause unconditional arbitrary command execution
0
Attacker Value
Unknown
CVE-2022-28556
Disclosure Date: May 04, 2022 (last updated February 23, 2025)
Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin is vulnerable to Buffer Overflow. The stack overflow vulnerability lies in the /goform/setpptpservercfg interface of the web. The sent post data startip and endip are copied to the stack using the sanf function, resulting in stack overflow. Similarly, this vulnerability can be used together with CVE-2021-44971
0
Attacker Value
Unknown
CVE-2021-44971
Disclosure Date: January 28, 2022 (last updated February 23, 2025)
Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE.