Show filters
20 Total Results
Displaying 11-20 of 20
Sort by:
Attacker Value
Unknown

CVE-2021-27254

Disclosure Date: March 05, 2021 (last updated February 22, 2025)
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of NETGEAR R7800. Authentication is not required to exploit this vulnerability. The specific flaw exists within the apply_save.cgi endpoint. This issue results from the use of hard-coded encryption key. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-12287.
Attacker Value
Unknown

CVE-2020-2499

Disclosure Date: December 23, 2020 (last updated February 22, 2025)
A hard-coded password vulnerability has been reported to affect earlier versions of QES. If exploited, this vulnerability could allow attackers to log in with a hard-coded password. QNAP has already fixed the issue in QES 2.1.1 Build 20200515 and later.
Attacker Value
Unknown

CVE-2020-7590

Disclosure Date: October 13, 2020 (last updated February 22, 2025)
A vulnerability has been identified in DCA Vantage Analyzer (All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797). Affected devices use a hard-coded password to protect the onboard database. This could allow an attacker to read and or modify the onboard database. Successful exploitation requires direct physical access to the device.
Attacker Value
Unknown

CVE-2020-12012

Disclosure Date: June 29, 2020 (last updated February 21, 2025)
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 have hard-coded administrative account credentials for the ExactaMix application. Successful exploitation of this vulnerability may allow an attacker with physical access to gain unauthorized access to view/update system configuration or data. This could impact confidentiality and integrity of the system and risk exposure of sensitive information including PHI.
Attacker Value
Unknown

CVE-2020-12039

Disclosure Date: June 29, 2020 (last updated February 21, 2025)
Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed.
Attacker Value
Unknown

CVE-2020-12045

Disclosure Date: June 29, 2020 (last updated February 21, 2025)
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials.
Attacker Value
Unknown

CVE-2020-12037

Disclosure Date: June 29, 2020 (last updated February 21, 2025)
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.
Attacker Value
Unknown

CVE-2020-12047

Disclosure Date: June 29, 2020 (last updated February 21, 2025)
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials.
Attacker Value
Unknown

CVE-2020-12016

Disclosure Date: June 29, 2020 (last updated February 21, 2025)
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI.
Attacker Value
Unknown

CVE-2020-5351

Disclosure Date: April 07, 2020 (last updated February 23, 2025)
Dell EMC Data Protection Advisor versions 6.4, 6.5 and 18.1 contain an undocumented account with limited privileges that is protected with a hard-coded password. A remote unauthenticated malicious user with the knowledge of the hard-coded password may login to the system and gain read-only privileges.