Unknown
CVE-2021-0207
CVE ID
AttackerKB requires a CVE ID in order to pull vulnerability data and references from the CVE list and the National Vulnerability Database. If available, please supply below:
Add References:
Unknown
(0 users assessed)Unknown
(0 users assessed)Unknown
Unknown
Unknown
MITRE ATT&CK
Collection
Command and Control
Credential Access
Defense Evasion
Discovery
Execution
Exfiltration
Impact
Initial Access
Lateral Movement
Persistence
Privilege Escalation
Topic Tags
Description
An improper interpretation conflict of certain data between certain software components within the Juniper Networks Junos OS devices does not allow certain traffic to pass through the device upon receipt from an ingress interface filtering certain specific types of traffic which is then being redirected to an egress interface on a different VLAN. This causes a Denial of Service (DoS) to those clients sending these particular types of traffic. Such traffic being sent by a client may appear genuine, but is non-standard in nature and should be considered as potentially malicious, and can be targeted to the device, or destined through it for the issue to occur. This issues affects IPv4 and IPv6 traffic. An indicator of compromise may be found by checking log files. You may find that traffic on the input interface has 100% of traffic flowing into the device, yet the egress interface shows 0 pps leaving the device. For example: [show interfaces “interface” statistics detail] Output between two interfaces would reveal something similar to: Ingress, first interface: —————————— Interface Link Input packets (pps) Output packets (pps) et-0/0/0 Up 9999999999 (9999) 1 (0) —————————— Egress, second interface: —————————— Interface Link Input packets (pps) Output packets (pps) et-0/0/1 Up 0 (0) 9999999999 (0) —————————— Dropped packets will not show up in DDoS monitoring/protection counters as issue is not caused by anti-DDoS protection mechanisms. This issue affects: Juniper Networks Junos OS: 17.3 versions prior to 17.3R3-S7 on NFX250, QFX5K Series, EX4600; 17.4 versions prior to 17.4R2-S11, 17.4R3-S3 on NFX250, QFX5K Series, EX4600; 18.1 versions prior to 18.1R3-S9 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4600; 18.2 versions prior to 18.2R3-S3 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600; 18.3 versions prior to 18.3R3-S1 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600 Series; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600 Series; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600 Series; 19.2 versions prior to 19.2R1-S5, 19.2R2 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600 Series; 19.3 versions prior to 19.3R2-S3, 19.3R3 on NFX250, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600 Series; 19.4 versions prior to 19.4R1-S2, 19.4R2 on NFX250, NFX350, QFX5K Series, EX2300 Series, EX3400 Series, EX4300 Multigigabit, EX4600 Series. This issue does not affect Junos OS releases prior to 17.2R2.
Add Assessment
No one has assessed this topic. Be the first to add your voice to the community.
CVSS V3 Severity and Metrics
General Information
Vendors
- juniper
Products
- junos 17.3,
- junos 17.4,
- junos 18.1,
- junos 18.2,
- junos 18.3,
- junos 18.4,
- junos 19.1,
- junos 19.2,
- junos 19.3,
- junos 19.4
References
Advisory
Additional Info
Technical Analysis
Report as Emergent Threat Response
Report as Exploited in the Wild
CVE ID
AttackerKB requires a CVE ID in order to pull vulnerability data and references from the CVE list and the National Vulnerability Database. If available, please supply below: