Attacker Value
Unknown
(0 users assessed)
Exploitability
Unknown
(0 users assessed)
User Interaction
None
Privileges Required
None
Attack Vector
Network
0

CVE-2022-43704

Disclosure Date: January 20, 2023
Add MITRE ATT&CK tactics and techniques that apply to this CVE.

Description

The Sinilink XY-WFT1 WiFi Remote Thermostat, running firmware 1.3.6, allows an attacker to bypass the intended requirement to communicate using MQTT. It is possible to replay Sinilink aka SINILINK521 protocol (udp/1024) commands interfacing directly with the target device. This, in turn, allows for an attack to control the onboard relay without requiring authentication via the mobile application. This might result in an unacceptable temperature within the target device’s physical environment.

Add Assessment

No one has assessed this topic. Be the first to add your voice to the community.

CVSS V3 Severity and Metrics
Base Score:
5.9 Medium
Impact Score:
3.6
Exploitability Score:
2.2
Vector:
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N
Attack Vector (AV):
Network
Attack Complexity (AC):
High
Privileges Required (PR):
None
User Interaction (UI):
None
Scope (S):
Unchanged
Confidentiality (C):
None
Integrity (I):
High
Availability (A):
None

General Information

Vendors

Additional Info

Technical Analysis