CVE-2018-4844

Disclosure Date: March 20, 2018
Add MITRE ATT&CK tactics and techniques that apply to this CVE.

Description

A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app’s sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app’s folder on a mobile device. The vulnerability could allow reading data from and writing data to the app’s folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Add Assessment

No one has assessed this topic. Be the first to add your voice to the community.

CVSS V3 Severity and Metrics
Base Score:
6.7 Medium
Impact Score:
5.2
Exploitability Score:
1.5
Vector:
CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N
Attack Vector (AV):
Adjacent_network
Attack Complexity (AC):
Low
Privileges Required (PR):
Low
User Interaction (UI):
Required
Scope (S):
Unchanged
Confidentiality (C):
High
Integrity (I):
High
Availability (A):
None