Show filters
1 Total Results
Displaying 1-1 of 1
Sort by:
Attacker Value
Unknown
CVE-2022-26477
Disclosure Date: June 27, 2022 (last updated November 29, 2024)
The Security Team noticed that the termination condition of the for loop in the readExternal method is a controllable variable, which, if tampered with, may lead to CPU exhaustion. As a fix, we added an upper bound and termination condition in the read and write logic. We classify it as a "low-priority but useful improvement". SystemDS is a distributed system and needs to serialize/deserialize data but in many code paths (e.g., on Spark broadcast/shuffle or writing to sequence files) the byte stream is anyway protected by additional CRC fingerprints. In this particular case though, the number of decoders is upper-bounded by twice the number of columns, which means an attacker would need to modify two entries in the byte stream in a consistent manner. By adding these checks robustness was strictly improved with almost zero overhead. These code changes are available in versions higher than 2.2.1.
0