Show filters
13 Total Results
Displaying 1-10 of 13
Sort by:
Attacker Value
Unknown

CVE-2024-7226

Disclosure Date: July 30, 2024 (last updated August 14, 2024)
A vulnerability was found in SourceCodester Medicine Tracker System 1.0. It has been declared as problematic. This vulnerability affects unknown code of the file /classes/Users.php?f=save_user of the component Password Change Handler. The manipulation leads to cross-site request forgery. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272806 is the identifier assigned to this vulnerability.
Attacker Value
Unknown

CVE-2024-6419

Disclosure Date: July 01, 2024 (last updated August 16, 2024)
A vulnerability classified as critical was found in SourceCodester Medicine Tracker System 1.0. This vulnerability affects unknown code of the file /classes/Master.php?f=save_medicine. The manipulation of the argument id leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-270010 is the identifier assigned to this vulnerability.
Attacker Value
Unknown

CVE-2024-6418

Disclosure Date: June 30, 2024 (last updated August 16, 2024)
A vulnerability classified as critical has been found in SourceCodester Medicine Tracker System 1.0. This affects an unknown part of the file /classes/Users.php?f=register_user. The manipulation of the argument username leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-270009 was assigned to this vulnerability.
Attacker Value
Unknown

CVE-2023-7134

Disclosure Date: December 28, 2023 (last updated January 03, 2024)
A vulnerability was found in SourceCodester Medicine Tracking System 1.0. It has been rated as critical. This issue affects some unknown processing. The manipulation of the argument page leads to path traversal: '../filedir'. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-249137 was assigned to this vulnerability.
Attacker Value
Unknown

CVE-2023-7123

Disclosure Date: December 28, 2023 (last updated January 05, 2024)
A vulnerability, which was classified as critical, has been found in SourceCodester Medicine Tracking System 1.0. This issue affects some unknown processing of the file /classes/Master.php? f=save_medicine. The manipulation of the argument id/name/description leads to sql injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-249095.
Attacker Value
Unknown

CVE-2023-5581

Disclosure Date: October 14, 2023 (last updated October 20, 2023)
A vulnerability classified as problematic was found in SourceCodester Medicine Tracker System 1.0. This vulnerability affects unknown code of the file index.php. The manipulation of the argument page leads to cross site scripting. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-242146 is the identifier assigned to this vulnerability.
Attacker Value
Unknown

CVE-2023-30112

Disclosure Date: April 26, 2023 (last updated October 08, 2023)
Medicine Tracker System in PHP 1.0.0 is vulnerable to SQL Injection.
Attacker Value
Unknown

CVE-2023-30111

Disclosure Date: April 26, 2023 (last updated October 08, 2023)
Medicine Tracker System in PHP 1.0.0 is vulnerable to Cross Site Scripting (XSS).
Attacker Value
Unknown

CVE-2023-30106

Disclosure Date: April 26, 2023 (last updated October 08, 2023)
Sourcecodester Medicine Tracker System in PHP 1.0.0 is vulnerable to Cross Site Scripting (XSS) via page=about.
Attacker Value
Unknown

CVE-2023-30458

Disclosure Date: April 24, 2023 (last updated October 08, 2023)
A username enumeration issue was discovered in Medicine Tracker System 1.0. The login functionality allows a malicious user to guess a valid username due to a different response time from invalid usernames. When one enters a valid username, the response time increases depending on the length of the supplied password.