Show filters
36 Total Results
Displaying 1-10 of 36
Sort by:
Attacker Value
Unknown

CVE-2022-22226

Disclosure Date: October 12, 2022 (last updated October 08, 2023)
In VxLAN scenarios on EX4300-MP, EX4600, QFX5000 Series devices an Uncontrolled Memory Allocation vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an unauthenticated adjacently located attacker sending specific packets to cause a Denial of Service (DoS) condition by crashing one or more PFE's when they are received and processed by the device. Upon automatic restart of the PFE, continued processing of these packets will cause the memory leak to reappear. Depending on the volume of packets received the attacker may be able to create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on EX4300-MP, EX4600, QFX5000 Series: 17.1 version 17.1R1 and later versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R1-S8, 18.4R2-S6, 18.4R3-S6; 19.1 versions prior to 19.…
Attacker Value
Unknown

CVE-2022-22154

Disclosure Date: January 12, 2022 (last updated October 07, 2023)
In a Junos Fusion scenario an External Control of Critical State Data vulnerability in the Satellite Device (SD) control state machine of Juniper Networks Junos OS allows an attacker who is able to make physical changes to the cabling of the device to cause a denial of service (DoS). An SD can get rebooted and subsequently controlled by an Aggregation Device (AD) which does not belong to the original Fusion setup and is just connected to an extended port of the SD. To carry out this attack the attacker needs to have physical access to the cabling between the SD and the original AD. This issue affects: Juniper Networks Junos OS 16.1R1 and later versions prior to 18.4R3-S10; 19.1 versions prior to 19.1R3-S7; 19.2 versions prior to 19.2R3-S4. This issue does not affect Juniper Networks Junos OS versions prior to 16.1R1.
Attacker Value
Unknown

CVE-2022-22160

Disclosure Date: January 12, 2022 (last updated October 07, 2023)
An Unchecked Error Condition vulnerability in the subscriber management daemon (smgd) of Juniper Networks Junos OS allows an unauthenticated adjacent attacker to cause a crash of and thereby a Denial of Service (DoS). In a subscriber management / broadband edge environment if a single session group configuration contains dual-stack and a pp0 interface, smgd will crash and restart every time a PPPoE client sends a specific message. This issue affects Juniper Networks Junos OS on MX Series: 16.1 version 16.1R1 and later versions prior to 18.4R3-S10; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R3-S5; 20.1 versions prior to 20.1R3-S3; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R2. This issue does not affect Juniper Networks Junos OS versions prior to 16.1R1.
Attacker Value
Unknown

CVE-2021-31382

Disclosure Date: October 13, 2021 (last updated November 28, 2024)
On PTX1000 System, PTX10002-60C System, after upgrading to an affected release, a Race Condition vulnerability between the chassis daemon (chassisd) and firewall process (dfwd) of Juniper Networks Junos OS, may update the device's interfaces with incorrect firewall filters. This issue only occurs when upgrading the device to an affected version of Junos OS. Interfaces intended to have protections may have no protections assigned to them. Interfaces with one type of protection pattern may have alternate protections assigned to them. Interfaces intended to have no protections may have protections assigned to them. These firewall rule misassignments may allow genuine traffic intended to be stopped at the interface to propagate further, potentially causing disruptions in services by propagating unwanted traffic. An attacker may be able to take advantage of these misassignments. This issue affects Juniper Networks Junos OS on PTX1000 System: 17.2 versions 17.2R1 and later versions prior to…
Attacker Value
Unknown

CVE-2021-31379

Disclosure Date: October 13, 2021 (last updated November 28, 2024)
An Incorrect Behavior Order vulnerability in the MAP-E automatic tunneling mechanism of Juniper Networks Junos OS allows an attacker to send certain malformed IPv4 or IPv6 packets to cause a Denial of Service (DoS) to the PFE on the device which is disabled as a result of the processing of these packets. Continued receipt and processing of these malformed IPv4 or IPv6 packets will create a sustained Denial of Service (DoS) condition. This issue only affects MPC 7/8/9/10/11 cards, when MAP-E IP reassembly is enabled on these cards. An indicator of compromise is the output: FPC ["FPC ID" # e.g. "0"] PFE #{PFE ID # e.g. "1"] : Fabric Disabled Example: FPC 0 PFE #1 : Fabric Disabled when using the command: show chassis fabric fpcs An example of a healthy result of the command use would be: user@device-re1> show chassis fabric fpcs Fabric management FPC state: FPC 0 PFE #0 Plane 0: Plane enabled Plane 1: Plane enabled Plane 2: Plane enabled Plane 3: Plane enabled Plane 4: Plane enabled Pla…
0
Attacker Value
Unknown

CVE-2020-1665

Disclosure Date: October 14, 2020 (last updated February 22, 2025)
On Juniper Networks MX Series and EX9200 Series, in a certain condition the IPv6 Distributed Denial of Service (DDoS) protection might not take affect when it reaches the threshold condition. The DDoS protection allows the device to continue to function while it is under DDoS attack, protecting both the Routing Engine (RE) and the Flexible PIC Concentrator (FPC) during the DDoS attack. When this issue occurs, the RE and/or the FPC can become overwhelmed, which could disrupt network protocol operations and/or interrupt traffic. This issue does not affect IPv4 DDoS protection. This issue affects MX Series and EX9200 Series with Trio-based PFEs (Packet Forwarding Engines). Please refer to https://kb.juniper.net/KB25385 for the list of Trio-based PFEs. This issue affects Juniper Networks Junos OS on MX series and EX9200 Series: 17.2 versions prior to 17.2R3-S4; 17.2X75 versions prior to 17.2X75-D102, 17.2X75-D110; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S11, 17.4R3…
0
Attacker Value
Unknown

CVE-2020-1679

Disclosure Date: October 14, 2020 (last updated February 22, 2025)
On Juniper Networks PTX and QFX Series devices with packet sampling configured using tunnel-observation mpls-over-udp, sampling of a malformed packet can cause the Kernel Routing Table (KRT) queue to become stuck. KRT is the module within the Routing Process Daemon (RPD) that synchronized the routing tables with the forwarding tables in the kernel. This table is then synchronized to the Packet Forwarding Engine (PFE) via the KRT queue. Thus, when KRT queue become stuck, it can lead to unexpected packet forwarding issues. An administrator can monitor the following command to check if there is the KRT queue is stuck: user@device > show krt state ... Number of async queue entries: 65007 <--- this value keep on increasing. When this issue occurs, the following message might appear in the /var/log/messages: DATE DEVICE kernel: %KERN-3: rt_pfe_veto: Too many delayed route/nexthop unrefs. Op 2 err 55, rtsm_id 5:-1, msg type 2 DATE DEVICE kernel: %KERN-3: rt_pfe_veto: Memory usage of M_RTNEXT…
0
Attacker Value
Unknown

CVE-2020-1656

Disclosure Date: October 14, 2020 (last updated February 22, 2025)
The DHCPv6 Relay-Agent service, part of the Juniper Enhanced jdhcpd daemon shipped with Juniper Networks Junos OS has an Improper Input Validation vulnerability which will result in a Denial of Service (DoS) condition when a DHCPv6 client sends a specific DHPCv6 message allowing an attacker to potentially perform a Remote Code Execution (RCE) attack on the target device. Continuous receipt of the specific DHCPv6 client message will result in an extended Denial of Service (DoS) condition. If adjacent devices are also configured to relay DHCP packets, and are not affected by this issue and simply transparently forward unprocessed client DHCPv6 messages, then the attack vector can be a Network-based attack, instead of an Adjacent-device attack. No other DHCP services are affected. Receipt of the packet without configuration of the DHCPv6 Relay-Agent service, will not result in exploitability of this issue. This issue affects Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S15; …
0
Attacker Value
Unknown

CVE-2020-1644

Disclosure Date: July 08, 2020 (last updated February 21, 2025)
On Juniper Networks Junos OS and Junos OS Evolved devices, the receipt of a specific BGP UPDATE packet causes an internal counter to be incremented incorrectly, which over time can lead to the routing protocols process (RPD) crash and restart. This issue affects both IBGP and EBGP multihop deployment in IPv4 or IPv6 network. This issue affects: Juniper Networks Junos OS: 17.2X75 versions prior to 17.2X75-D105.19; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S10, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S4; 18.2X75 versions prior to 18.2X75-D13, 18.2X75-D411.1, 18.2X75-D420.18, 18.2X75-D52.3, 18.2X75-D60; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3-S2; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2-S2, 19.3R3; 19.4 versions prior to 19.4R1-S2, 19.4R2. Juniper Networks Junos OS Evolved: any rel…
Attacker Value
Unknown

CVE-2020-1651

Disclosure Date: July 08, 2020 (last updated February 21, 2025)
On Juniper Networks MX series, receipt of a stream of specific Layer 2 frames may cause a memory leak resulting in the packet forwarding engine (PFE) on the line card to crash and restart, causing traffic interruption. By continuously sending this stream of specific layer 2 frame, an attacker connected to the same broadcast domain can repeatedly crash the PFE, causing a prolonged Denial of Service (DoS). This issue affects Juniper Networks Junos OS on MX Series: 17.2 versions prior to 17.2R3-S4; 17.2X75 versions prior to 17.2X75-D105.19; 17.3 versions prior to 17.3R3-S7; 17.4 versions prior to 17.4R1-S3, 17.4R2; 18.1 versions prior to 18.1R2. This issue does not affect Juniper Networks Junos OS releases prior to 17.2R1.