CVE-2023-3346
Disclosure Date: August 03, 2023 (last updated January 30, 2024)
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in MITSUBSHI CNC Series allows a remote unauthenticated attacker to cause Denial of Service (DoS) condition and execute arbitrary code on the product by sending specially crafted packets. In addition, system reset is required for recovery.
0
Attacker Value
Unknown
CVE-2020-7802
Disclosure Date: April 14, 2020 (last updated February 21, 2025)
The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Incorrect Default Permissions (CWE-276) vulnerability. The affected product is vulnerable to insufficient default permissions, which could allow an attacker to view network configurations through SNMP communication. This is a different issue than CVE-2019-16879, CVE-2019-20045, CVE-2019-20046, CVE-2020-7800, and CVE-2020-7801.
0
Attacker Value
Unknown
CVE-2020-7800
Disclosure Date: April 14, 2020 (last updated February 21, 2025)
The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability. The affected product is vulnerable to specially crafted TCP packets, which can cause the device to shut down or reboot and lose configuration settings. This is a different issue than CVE-2019-16879, CVE-2019-20045, CVE-2019-20046, CVE-2020-7801, and CVE-2020-7802.
0
Attacker Value
Unknown
CVE-2019-16879
Disclosure Date: April 14, 2020 (last updated February 21, 2025)
The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulnerability. The affected product does not require authentication for TELNET access, which may allow an attacker to change configuration or perform other malicious activities.
0
Attacker Value
Unknown
CVE-2020-7801
Disclosure Date: April 14, 2020 (last updated February 21, 2025)
The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Exposure of Sensitive Information to an Unauthorized Actor (CWE-200) vulnerability. The affected product is vulnerable to information exposure over the SNMP protocol. This is a different issue than CVE-2019-16879, CVE-2019-20045, CVE-2019-20046, CVE-2020-7800, and CVE-2020-7802.
0
Attacker Value
Unknown
CVE-2019-20046
Disclosure Date: February 14, 2020 (last updated February 21, 2025)
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue than CVE-2019-16879 and CVE-2019-20045.
0
Attacker Value
Unknown
CVE-2019-20045
Disclosure Date: February 14, 2020 (last updated February 21, 2025)
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and CVE-2019-20046.
0
Attacker Value
Unknown
CVE-2018-16593
Disclosure Date: June 19, 2019 (last updated November 27, 2024)
The Photo Sharing Plus component on Sony Bravia TV through 8.587 devices allows Shell Metacharacter Injection.
0
Attacker Value
Unknown
CVE-2018-16594
Disclosure Date: June 19, 2019 (last updated November 27, 2024)
The Photo Sharing Plus component on Sony Bravia TV through 8.587 devices allows Directory Traversal.
0
Attacker Value
Unknown
CVE-2018-16595
Disclosure Date: June 19, 2019 (last updated November 27, 2024)
The Photo Sharing Plus component on Sony Bravia TV through 8.587 devices has a Buffer Overflow.