CVE-2019-10938

Disclosure Date: August 02, 2019 (last updated November 27, 2024)
A vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions < V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions < V8.01), Siemens Power Meters Series 9410 (All versions < V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is executed before firmware verification in the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Attacker Value
Unknown

CVE-2019-10930

Disclosure Date: July 11, 2019 (last updated November 27, 2024)
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions). A remote attacker could use specially crafted packets sent to port 443/TCP to upload, download or delete files in certain parts of the file system.
0
Attacker Value
Unknown

CVE-2019-10931

Disclosure Date: July 11, 2019 (last updated November 27, 2024)
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition.
Attacker Value
Unknown

CVE-2018-10936

Disclosure Date: August 30, 2018 (last updated November 08, 2023)
A weakness was found in postgresql-jdbc before version 42.2.5. It was possible to provide an SSL Factory and not check the host name if a host name verifier was not provided to the driver. This could lead to a condition where a man-in-the-middle attacker could masquerade as a trusted server by providing a certificate for the wrong host, as long as it was signed by a trusted CA.
0
Attacker Value
Unknown

CVE-2018-2418

Disclosure Date: May 09, 2018 (last updated November 26, 2024)
SAP MaxDB ODBC driver (all versions before 7.9.09.07) allows an attacker to inject code that can be executed by the application. An attacker could thereby control the behavior of the application.
0
Attacker Value
Unknown

CVE-2017-1297

Disclosure Date: June 27, 2017 (last updated November 26, 2024)
IBM DB2 for Linux, UNIX and Windows 9.2, 10.1, 10.5, and 11.1 (includes DB2 Connect Server) is vulnerable to a stack-based buffer overflow, caused by improper bounds checking which could allow a local attacker to execute arbitrary code. IBM X-Force ID: 125159.
0
Attacker Value
Unknown

CVE-2017-1105

Disclosure Date: June 27, 2017 (last updated November 26, 2024)
IBM DB2 for Linux, UNIX and Windows 9.2, 10.1, 10.5, and 11.1 (includes DB2 Connect Server) is vulnerable to a buffer overflow that could allow a local user to overwrite DB2 files or cause a denial of service. IBM X-Force ID: 120668.
0
Attacker Value
Unknown

CVE-2014-0777

Disclosure Date: April 11, 2014 (last updated October 05, 2023)
The Modbus slave/outstation driver in the OPC Drivers 1.0.20 and earlier in IOServer OPC Server allows remote attackers to cause a denial of service (out-of-bounds read and daemon crash) via a crafted packet.
0
Attacker Value
Unknown

CVE-2013-0662

Disclosure Date: April 01, 2014 (last updated October 05, 2023)
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
0
Attacker Value
Unknown

CVE-2013-5987

Disclosure Date: January 21, 2014 (last updated October 05, 2023)
Unspecified vulnerability in NVIDIA graphics driver Release 331, 325, 319, 310, and 304 allows local users to bypass intended access restrictions for the GPU and gain privileges via unknown vectors.